Discussion. Introduction of the implantable Doppler system did not lead to an increased salvage rate of compromised flaps: a multivariate analysis.

نویسندگان

  • Charles E Butler
  • Matthew M Hanasono
چکیده

BACKGROUND The Cook-Swartz implantable Doppler system was introduced at the Uppsala University Hospital to ease free flap monitoring and improve salvage rates by an earlier detection of vascular compromise. The aim of the current analysis was to investigate whether the system indeed improved the salvage rate of revisions. METHODS All cases that needed revision among a consecutive series of patients being monitored with the implantable Doppler system between June of 2006 and January of 2009 were compared with a similar set of patients operated on before the introduction of the implantable Doppler system over an equal time span monitored with conventional methods. Data were extracted from the medical files of the patients. Logistic regression was used to identify factors associated with the outcome of the revision. Values of p < 0.05 were considered statistically significant. RESULTS A total of 327 flaps were monitored with the implantable Doppler system, of which 35 needed revision. In the control group, 303 flaps were included, of which 40 needed revision. The revision was successful in 69 percent of the cases in the implantable Doppler system group; in the group monitored by only conventional methods, this rate was 60 percent. Univariate analysis showed no statistical difference between these success rates (p = 0.441; odds ratio, 1.455; 95 percent confidence interval, 0.560 to 3.775). Multivariate analysis did not show a statistical difference either (p = 0.799; odds ratio, 1.143; 95 percent confidence interval, 0.410 to 3.182). CONCLUSION The introduction of the implantable Doppler system did not lead to a significant increase in the salvage rate of revised flaps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction.

OBJECTIVE To determine if the implantable Cook-Swartz Doppler Flow Monitoring System (Cook Vascular Inc, Vandergrift, Pennsylvania) improves surgical salvage rates for compromised free flaps. DESIGN Retrospective medical record review spanning 2002 to 2006 for a large head and neck oncology program. SETTING A tertiary care hospital. PATIENTS A consecutive series of 351 patients (244 men a...

متن کامل

Implantable Doppler Probes for Postoperatively Monitoring Free Flaps: Efficacy. A Systematic Review and Meta-analysis

BACKGROUND Although clinical assessment remains the gold standard for monitoring the circulation of free flaps, several adjunct techniques promote timely salvage by detecting circulation compromise early. The objective of this systematic review was to evaluate the efficacy of an implantable Doppler probe for postoperatively monitoring free flaps. MATERIALS AND METHODS English-language article...

متن کامل

Current evidence for postoperative monitoring of microvascular free flaps: a systematic review.

BACKGROUND Despite a plethora of monitoring techniques reported in the literature, only a small number of studies directly address clinical relevant end points, such as the flap salvage rate and false-positive rate. METHOD We conducted a systematic review of current evidence regarding the postoperative monitoring of microvascular free-tissue transfer via extensive electronic and manual search...

متن کامل

Postoperative monitoring of free flap reconstruction: A comparison of external Doppler ultrasonography and the implantable Doppler probe.

HYPOTHESIS The time to detection of vascular compromise and the postoperative time to re-exploration are shorter using the implantable Doppler (ID) probe, thereby resulting in earlier surgical re-exploration and a higher flap salvage rate. METHODS A single-centre experience with 176 consecutive free flap reconstructions in 167 patients from 2000 to 2008 in a university-based teaching hospital...

متن کامل

Postoperative monitoring of free flaps in autologous breast reconstruction: a multicenter comparison of 398 flaps using clinical monitoring, microdialysis, and the implantable Doppler probe.

Many techniques for flap monitoring following free tissue transfer have been described; however, there is little evidence that any of these techniques allow for greater rates of flap salvage over clinical monitoring alone. We sought to compare three established monitoring techniques across three experienced microsurgical centers in a comparable cohort of patients. A retrospective, matched cohor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Plastic and reconstructive surgery

دوره 125 6  شماره 

صفحات  -

تاریخ انتشار 2010