Resolution Acuity is better than Vernier Acuity

نویسندگان

  • THOM CARNEY
  • STANLEY A. KLEIN
چکیده

Our impressive sensitivity to vernier offsets as compared to resolution acuity has long inspired vision researchers to study the phenomena in great detail. In this study we use the test-pedestal framework to compare resolution and vernier acuity. In these experiments the test stimulus is the same for both tasks, only the pedestals differ. When thresholds are expressed in common units of test strength, vernier acuity thresholds are higher (worse) than for resolution and contrast discrimination tasks over the range of pedestal strengths tested. This apparent reversal of sensitivity is actually consistent with expectations based on the presumed underlying visual mechanisms involved in the tasks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cortical sources of Vernier acuity in the human visual system: An EEG-source imaging study

Vernier acuity determines the relative position of visual features with a precision better than the sampling resolution of cone receptors in the retina. Because Vernier displacement is thought to be mediated by orientation-tuned mechanisms, Vernier acuity is presumed to be processed in striate visual cortex (V1). However, there is considerable evidence suggesting that Vernier acuity is dependen...

متن کامل

Detection of Amblyopia Using Sweep VEP Vernier and Grating Acuity

Purpose Vernier and grating acuity can be measured with swept-parameter visual evoked potentials (sVEP). However, whether sVEP Vernier and grating acuities are comparable in predicting letter acuity has not been systematically evaluated. This study evaluated the validity and reliability of sVEP Vernier and grating acuity for the detection of amblyopia in adults. Methods Three types of acuity ...

متن کامل

The pattern of visual deficits in amblyopia.

Amblyopia is usually defined as a deficit in optotype (Snellen) acuity with no detectable organic cause. We asked whether this visual abnormality is completely characterized by the deficit in optotype acuity, or whether it has distinct forms that are determined by the conditions associated with the acuity loss, such as strabismus or anisometropia. To decide this issue, we measured optotype acui...

متن کامل

Hyperacuity deficits in anisometropic and strabismic amblyopes with known ages of onset

In order to evaluate the influence of etiology of amblyopia and of age at onset of amblyopia on the resulting constellation of spatial vision deficits, resolution/vernier and recognition/resolution acuity ratios were measured in groups of children with either strabismic amblyopia or anisometropic amblyopia with known ages of onset. Strabismic amblyopia with infantile onset (<9 months) and strab...

متن کامل

Assessment of vernier acuity development using the “Equivalent Intrinsic Blur” paradigm

Vernier acuity in human infants is more than two orders of magnitude poorer than in adults and does not appear to reach adult levels until well beyond the first postnatal year. One source of these developmental differences in vernier acuity may be the presence of levels of intrinsic blur that are higher in infants than in adults. We investigated this hypothesis by measuring vernier acuity in 3-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 37  شماره 

صفحات  -

تاریخ انتشار 1997