Determining the incident electron fluence for Monte Carlo-based photon treatment planning using a standard measured data set.

نویسندگان

  • Paul J Keall
  • Jeffrey V Siebers
  • Bruce Libby
  • Radhe Mohan
چکیده

An accurate dose calculation in phantom and patient geometries requires an accurate description of the radiation source. Errors in the radiation source description are propagated through the dose calculation. With the emergence of linear accelerators whose dosimetric characteristics are similar to within measurement uncertainty, the same radiation source description can be used as the input to dose calculation for treatment planning at many institutions with the same linear accelerator model. Our goal in the current research was to determine the initial electron fluence above the linear accelerator target for such an accelerator to allow a dose calculation in water to within 1% or 1 mm of the measured data supplied by the manufacturer. The method used for both the radiation source description and the patient transport was Monte Carlo. The linac geometry was input into the Monte Carlo code using the accelerator's manufacturer's specifications. Assumptions about the initial electron source above the target were made based on previous studies. The free parameters derived for the calculations were the mean energy and radial Gaussian width of the initial electron fluence and the target density. A combination of the free parameters yielded an initial electron fluence that, when transported through the linear accelerator and into the phantom, allowed a dose-calculation agreement to the experimental ion chamber data to within the specified criteria at both 6 and 18 MV nominal beam energies, except near the surface, particularly for the 18 MV beam. To save time during Monte Carlo treatment planning, the initial electron fluence was transported through part of the treatment head to a plane between the monitor chambers and the jaws and saved as phase-space files. These files are used for clinical Monte Carlo-based treatment planning and are freely available from the authors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study

Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. The most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a Neptun 10PC linac using the Monte Carlo (MC) code. Materials and Methods: The lina...

متن کامل

A comparative Monte Carlo study on 6MV photon beam characteristics of Varian 21EX and Elekta SL-25 linacs

Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...

متن کامل

An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method

Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...

متن کامل

A Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment

Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique.  Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...

متن کامل

Evaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study

Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2003