Improved common-path optical heterodyne interferometer for measuring small optical rotation angle of chiral medium

نویسندگان

  • Ju-Yi Lee
  • Der-Chin Su
چکیده

An improved common-path optical heterodyne interferometry for measuring small optical rotation angle of chiral liquid is presented. The optical rotation angle can be determined by the phase difference between the test and reference signals. By means of inserting a phase retarder behind the test sample, the measuring resolution of optical rotation angle is greatly enhanced. The theoretical prediction indicates the resolution is better than 3.5 · 10 5 degree. 2005 Elsevier B.V. All rights reserved. PACS: 07.60. j; 33.55.A; 78.20.Ek

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models

The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...

متن کامل

A Sensitivity-Enhanced Optical Heterodyne Polarimeter for the Measurement of Optical Rotation Angle of Chiral Media

A novel heterodyne polarimeter is designed to measure the concentration of chiral media. Optical common-path for the interference of the TE and TM waves, after a polarizer, is set up in our system to reduce noises from the environment. A phase-variable waveplate is placed behind the sample to enhance the phase signal change of rotation of polarization introduced by the sample itself. This enhan...

متن کامل

Error Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer

A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...

متن کامل

Improved Small-Angle Sensor Based on Total-Internal Reflection and Surface Plasmon Resonance in Heterodyne Interferometry

In this paper, an improved small-angle sensor based on total-internal reflection (TIR) and surface plasmon resonance (SPR) in heterodyne interferometry (HI) is proposed. The improved small-angle sensor is designed as a reflective elongated prism made of BK7 glass. The shorter-side surface of the reflective elongated prism was coated with a 2 nm Ti film and a 45.5 nm Au film, but the longer-side...

متن کامل

An Accuracy Analysis of Small Angle Measurement Using the Optical Vortex Interferometer

In recent years a lot of effort has been put into testing and improving the idea of a three-beam interferometer known as Optical Vortex Interferometer (OVI). Devices based on the idea of an OVI allow, among other things, measuring small rotation angles of the wave [1]. In this paper complex statistical analysis has been used for the results of the small-angle rotation wave measuring method. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005