Heat generated by hip resurfacing prostheses: an in vivo pilot study.
نویسنده
چکیده
In order to determine the magnitude of temperature increases in resurfaced hips, temperature sensors were placed percutaneously in both hip joints of 12 volunteer patients who had 1 or both joints resurfaced. Temperature recordings were made with patients at rest (baseline) and after patients walked for 20 and 60 minutes. The hip resurfacing procedures were performed 12 to 36 months prior to this study using 9 different acetabular bearing surface components. At baseline (resting), a ceramic femoral prosthesis articulating with a poly-ether-ether-ketone (PEEK) acetabular prosthesis generated a temperature increase of 4°C compared to a normal contralateral hip. After 60 minutes of walking, a ceramic femoral prosthesis articulating with a polyurethane acetabular prosthesis generated a temperature increase of 5°C, whereas a ceramic femoral prosthesis articulating with a metal acetabular prosthesis generated a temperature increase of 6°C, a cobalt-chromium alloy femoral prosthesis on a polyethylene acetabular prosthesis generated a temperature increase of 7°C, and a cobalt-chromium alloy metal-on-metal prosthesis generated a temperature increase of 8°C. Resurfaced hips generate more heat than arthritic and normal hips, and arthritic hips generate more heat than normal hips. A resurfaced hip with a ceramic femoral and PEEK or polyurethane acetabulum generated less heat than a resurfaced hip of the same design using a cobalt-chromium femur and either cobalt-chromium, or polyethylene for the acetabulum. Frictional heat generated in a resurfaced hip is not immediately dissipated and may result in increased bearing surface wear. Extended periods of elevated temperature within joints may inhibit periarticular cell growth and perhaps contribute to bone resorption or component loosening over the long term.
منابع مشابه
Five-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry.
BACKGROUND Articular Surface Replacement (ASR) hip prostheses, which have metal-on-metal bearing surfaces, were manufactured by DePuy Orthopaedics (Warsaw, Indiana) for use in both conventional total hip arthroplasty and hip resurfacing. Both the ASR XL Acetabular System and the ASR Hip Resurfacing System were recently recalled worldwide by the manufacturer. This report summarizes an analysis b...
متن کاملEffects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells.
Hip resurfacing with cobalt-chromium (CoCr) alloy was developed as a surgical alternative to total hip replacement. However, the biological effects of nanoparticles generated by wear at the metal-on-metal articulating surfaces has limited the success of such implants. The aim of this study was to investigate the effects of the combined exposure to CoCr nanoparticles and cobalt ions released fro...
متن کاملHave the media influenced the use of hip resurfacing arthroplasty? A review of UK print media
INTRODUCTION The aim of this study was to look at the different claims made about hip resurfacing arthroplasty in the popular UK print media and how this relates to findings in the scientific literature. METHODS A review of UK popular print media from January 1992 to June 2011 was performed using the Lexis(®) Library online news database. Only articles discussing the clinical results of hip ...
متن کاملAdverse reaction to metal debris: metallosis of the resurfaced hip
The greatest concern after metal-on-metal hip resurfacing may be the development of metallosis. Metallosis is an adverse tissue reaction to the metal debris generated by the prosthesis and can be seen with implants and joint prostheses. The reasons patients develop metallosis are multifactorial, involving patient, surgical, and implant factors. Contributing factors may include component malposi...
متن کاملPre-clinical evaluation of ceramic femoral head resurfacing prostheses using computational models and mechanical testing.
Ceramic-on-ceramic hip resurfacing can potentially offer the bone-conserving advantages of resurfacing while eliminating metal ion release. Thin-walled ceramic resurfacing heads are conceivable following developments in the strength and reliability of ceramic materials, but verification of new designs is required. The present study aimed to develop a mechanical pre-clinical analysis verificatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of long-term effects of medical implants
دوره 21 1 شماره
صفحات -
تاریخ انتشار 2011