Breast magnetic resonance imaging as a problem-solving modality in mammographic BI-RADS 3 lesions
نویسندگان
چکیده
The probability of a mammographic Breast Imaging Reporting and Data System (BI-RADS) 3 lesion being cancer is considered to be less than 2%. Therefore, the work-up of a mammographic BI-RADS 3 lesion should be biopsy or follow-up mammography after 6 months. However, most patients referred for biopsy have benign disease. Although the negative predictive value (NPV) of magnetic resonance imaging (MRI) is highest of all imaging techniques, it is not yet common practice to use breast MRI as a problem-solving modality to exclude patients for further diagnostic work-up. Therefore, in this meta-analysis the usefulness of breast MRI as a problem-solving modality in mammographic BI-RADS 3 lesions is investigated. After a systematic search only 5 out of 61 studies met the inclusion criteria. The NPV in 2 of those studies was reported to be 100%. It was concluded that MRI can be used as an adjunctive tool to mammographic BI-RADS 3 findings to exclude patients for further diagnostic work-up. The other 3 studies assessed the accuracy of MRI in mammographic BI-RADS 3 microcalcifications. These studies reported an NPV of MRI between 76% and 97%. Therefore, MRI cannot be implemented as a diagnostic tool to evaluate mammographic microcalcifications at this time. The first solid data indicate that breast MRI might be useful as a problem-solving modality to exclude patients with non-calcified mammographic BI-RADS 3 lesions for further diagnostic work-up. However, further research is needed to verify these results.
منابع مشابه
Is there any Correlation between Magnetic Resonance Imaging Features of Breast Lesions of BIRADS Category 4 with Histopathologic Results?
BACKGROUND To evaluate the correlation of magnetic resonance imaging (MRI) features of breast lesions of Breast Imaging Reporting and Database System (BI-RADS) category 4 with histopathologic results. MATERIALS AND METHODS In a prospective study between December 2013 and April 2015, patients with suspicious mammographic and/or ultrasound findings referred for Breast MRI were evaluated. Patien...
متن کاملEffect on biopsy technique of the breast imaging reporting and data system (BI-RADS) for nonpalpable mammographic abnormalities.
OBJECTIVE To determine if the breast imaging reporting and data system (BI-RADS) defines a group of patients with mammographic abnormalities in whom stereotactic core needle biopsy (SCNB) is appropriate. DESIGN A blinded retrospective validation sample. SETTING A university-affiliated hospital. PATIENTS One hundred and nine consecutive patients who underwent fine-wire localization breast ...
متن کاملBI-RADS categorization as a predictor of malignancy.
PURPOSE To determine the positive predictive value (PPV) of the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) categories 0, 2, 3, 4, and 5 by using BI-RADS terminology and by auditing data on needle localizations. MATERIALS AND METHODS Between April 1991 and December 1996, 1,400 mammographically guided needle localizations were performed in 1,109 patients. I...
متن کاملAdjacent vessel sign and breast imaging reporting and data system are valuable for diagnosis of benign and malignant breast lesions
The purpose of this study is to investigate whether an adjacent vessel sign (AVS) observed on the maximum intensity projections (MIPs) from the subtracted images can help distinguish between malignant and benign breast lesions and to test whether the combination of breast imaging reporting and data system (BI-RADS) category and AVS can increase the specificity and diagnostic accuracy of breast ...
متن کاملRadiological and Histological Correlation of Non-palpable Breast Lesions in Patients Submitted to Preoperative Marking According to Bi-rads Classification*
OBJECTIVE: To evaluate the positive predictive value for BI-RADS (Breast Imaging Reporting and Data System) categories 3, 4 and 5, correlating mammographic and histological diagnosis in non-palpable breast lesions. MATERIALS AND METHODS: Analytical-descriptive study of 169 women submitted to stereotactic localization for surgical biopsy of non-palpable breast lesions. Mammographic and histologi...
متن کامل