Pedicle screw surface coatings improve fixation in nonfusion spinal constructs.

نویسندگان

  • Vidyadhar V Upasani
  • Christine L Farnsworth
  • Tucker Tomlinson
  • Reid C Chambers
  • Shunji Tsutsui
  • Michael A Slivka
  • Andrew T Mahar
  • Peter O Newton
چکیده

STUDY DESIGN Biomechanical and histologic analysis. OBJECTIVE To compare the strength of the bone-screw interface of standard uncoated pedicle screws with screws treated with hydroxyapatite (HA), titanium plasma spray (TPS), and a composite HA-TPS coating. SUMMARY OF BACKGROUND DATA Transpedicular screw fixation has become the gold standard in the treatment of various thoracolumbar spinal conditions. Pedicle screw loosening, however, has been reported, especially in mechanically demanding constructs or in vertebrae with low bone mineral density. METHODS Six mature porcine were instrumented with 4 types of titanium monoaxial pedicle screws (uncoated, HA-only coated, TPS-only coated, and HA-TPS composite coated) in a systematically varied, single-blinded fashion. After a 3-month survival period, the spines were harvested en-bloc and "time zero" control screws were instrumented in adjacent vertebrae. Screw placement and bone mineral density were evaluated with a postharvest computed tomography, and the strength of the tissue-implant interface was evaluated with a torsional screw extraction analysis (60 screws) and a nondecalcified histologic analysis (16 screws). RESULTS At 3 months postoperative, peak torque increased for all 3 types of coated screws (increased fixation) and decreased significantly for the uncoated screws (P < 0.001). Although 3-month peak torque was not statistically different between the 3 screw coatings, 4 of 10 TPS-only coated screws had a peak torque that was nearly 0 (<0.1 N m) versus only 1 of 10 HA-only screws and 0 of 10 HA-TPS composite screws. Histologic analysis confirmed the biomechanical findings with improved osseointegration in the HA-only and HA-TPS composite screws. CONCLUSION Pedicle screw coatings that promote mechanical interlocking, TPS, or direct osteoblast bonding(HA) increased screw fixation in this nonfusion model. More non-HA coated screws, however, were thought to be "loose" with a nearly zero peak extraction torque and fibrous encapsulation. Increased osseointegration with HA may result in a decreased incidence of screw loosening and improved outcomes of transpedicular spinal instrumentation in nonfusion procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusion versus Nonfusion for Surgically Treated Thoracolumbar Burst Fractures: A Meta-Analysis

BACKGROUND Posterior pedicle screw fixation has become a popular method for treating thoracolumbar burst fractures. However, it remains unclear whether additional fusion could improve clinical and radiological outcomes. This meta-analysis was performed to evaluate the effectiveness of fusion as a supplement to pedicle screw fixation for thoracolumbar burst fractures. METHODOLOGY/PRINCIPAL FIN...

متن کامل

Cervical Pedicle Screw Placement in Sawbone Models and Unstable Cervical Traumatic Lesions by Using Para-Articular Mini-Laminotomy: A Novice Neurosurgeon’s Experience

Cervical pedicle screw has been shown to provide stronger fixation than other methods. Due to these virtue of biomechanical characteristic, pedicle screw fixation can be used in a wide range of cervical spinal disorders, and excellent clinical results have been reported. However, this procedure is technically demanding because of the great variation in pedicle dimension and angulations between ...

متن کامل

Biomechanical Analysis of Pedicle Screw Fixation for Thoracolumbar Burst Fractures.

Treatment of unstable thoracolumbar burst fractures remains controversial. Long-segment pedicle screw constructs may be stiffer and impart greater forces on adjacent segments compared with short-segment constructs, which may affect clinical performance and long-term out come. The purpose of this study was to biomechanically evaluate long-segment posterior pedicle screw fixation (LSPF) vs short-...

متن کامل

Technique, challenges and indications for percutaneous pedicle screw fixation.

Minimally invasive techniques in spinal surgery are increasing in popularity due to numerous potential advantages, including reduced length of stay, blood loss and requirements for post-operative analgesia as well as earlier return to work. This review discusses guidelines for safe implantation of percutaneous pedicle screws using an image intensifier technique. As indications for percutaneous ...

متن کامل

Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support

BACKGROUND Lumbosacral fusion is a relatively common procedure that is used in the management of an unstable spine. The anterior interbody cage has been involved to enhance the stability of a pedicle screw construct used at the lumbosacral junction. Biomechanical differences between polyaxial and monoaxial pedicle screws linked with various rod contours were investigated to analyze the respecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 34 4  شماره 

صفحات  -

تاریخ انتشار 2009