The effect of keyboard keyswitch make force on applied force and finger flexor muscle activity.

نویسندگان

  • D Rempel
  • E Serina
  • E Klinenberg
  • B J Martin
  • T J Armstrong
  • J A Foulke
  • S Natarajan
چکیده

The design of the force-displacement characteristics or 'feel' of keyboard keyswitches has been guided by preference and performance data; there has been very little information on how switch 'feel' alters muscle activity or applied force. This is a laboratory-based repeated measures design experiment to evaluate the effect of computer keyboard keyswitch design on applied finger force and muscle activity during a typing task. Ten experienced typists typed on three keyboards which differed in keyswitch make force (0.34, 0.47 and 1.02 N) while applied fingertip force and finger flexor electromyograms were recorded. The keyboard testing order was randomized and subjects typed on each keyboard for three trials, while data was collected for a minimum of 80 keystrokes per trial. No differences in applied fingertip force or finger flexor EMG were observed during typing on keyboards with switch make force of 0.34 or 0.47 N. However, applied fingertip force increased by approximately 40% (p < 0.05) and EMG activity increased by approximately 20% (p < 0.05) when the keyswitch make force was increased from 0.47 to 1.02 N. These results suggest that, in order to minimize the biomechanical loads to forearm tendons and muscles of keyboard users, keyswitches with a make force of 0.47 N or less should be considered over switches with a make force of 1.02 N.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of keyswitch stiffness on typing force, finger electromyography, and subjective discomfort.

The effects of keyswitch stiffness and key action on typing force, electromyography (EMG), and subjective preference were examined. Each subject's own keyboard (with an audible key click and key activation force of 0.72 N) and three keyboards with no key click that were identical in design but had different key activation forces (0.28 N, 0.56 N, and 0.83 N) were used. Subjects (24 female transc...

متن کامل

Keyswitch Orientation Can Reduce Finger Joint Torques During Tapping on a Computer Keyswitch

OBJECTIVE To examine the effects of keyswitch orientation on joint torques. BACKGROUND The fingertip produces primarily vertical forces during single-finger tapping on a computer keyswitch. However, horizontal force components within the sagittal plane of the finger could reduce net joint torques. METHOD Eleven participants tapped on a keyswitch oriented in three directions: vertical, tilte...

متن کامل

The Effects of Local Heating and Cooling of Arm on Maximal Isometric Force Generated by the Elbow Flexor Musculature in Male Subjects

Objectives: It is well known that neuromuscular function is temperature sensitive. Changing of muscle temperature can effect voluntary muscle contraction. The aim of this study was to investigate the effects of cooling and heating on maximal isometric force generated by the elbow flexor musculature in male subjects. Methods: Forty five healthy males encompassing 3 groups participated in the ...

متن کامل

In vivo forces generated by finger flexor muscles do not depend on the rate of fingertip loading during an isometric task.

Risk factors for activity-related tendon disorders of the hand include applied force, duration, and rate of loading. Understanding the relationship between external loading conditions and internal tendon forces can elucidate their role in injury and rehabilitation. The goal of this investigation is to determine whether the rate of force applied at the fingertip affects in vivo forces in the fle...

متن کامل

Effect of object width on muscle and joint forces during thumb-index finger grasping.

The objective of this study was to identify the impact of modifying the object width on muscle and joint forces while gripping objects. The experimental protocol consisted to maintain horizontally five objects of different widths (3.5, 4.5, 5.5, 6.5, and 7.5 cm) with a thumb-index finger grip. Subjects were required to grasp spontaneously the object without any instruction regarding the grip fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ergonomics

دوره 40 8  شماره 

صفحات  -

تاریخ انتشار 1997