The objective of this study is to develop sensitive and cost effective reverse phase high performance liquid chromatographic method for the estimation of Metoclopramide Hydrochloride in oral solid dosage formulations. A reverse chromatographic method was used with the mobile phase of Acetonitrile, 20m M Potassium dihydrogen phosphate buffer solution (pH 3 adjusted with orthophosphoric acid) in the ratio of 40:60. The column used was Waters C18 3.9×300mm µBondapak (RP). The flow rate of the mobile phase was 2ml/minute. The detector was set at the wavelength of 275nm.This method showed good sensitivity. The linearity was also found to be excellent (γ(2)=0.997) in the range of 5-75 μg/ml. No interfering peaks were observed at the retention time of Metoclopramide Hydrochloride when both placebo and blank samples were injected (Retention time =1.93min). The parameters such as specificity, linearity, range, accuracy, precision, system suitability, solution stability, detection and quantification limits were evaluated to validate this method. This method can effectively be used for quantitative analysis of Metoclopramide hydrochloride tablet formulations because of its specificity, accuracy and convenience of use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pakistan journal of pharmaceutical sciences

دوره 25 1  شماره 

صفحات  -

تاریخ انتشار 2012