Estimation of Organ Absorbed Doses in Patients from 99mTc-diphosphonate Using the Data of MIRDose Software

نویسندگان

  • Daryoush Shahbazi-Gahrouei
  • Mohsen Cheki
  • Masoud Moslehi
چکیده

The purpose of this study was to compare estimation of radiation absorbed doses to patients following bone scans with technetium-99m-labeled methylene diphosphonate (MDP) with the estimates given in MIRDose software. In this study, each patient was injected 25 mCi of (99m)Tc-MDP. Whole-body images from thirty patients were acquired by gamma camera at 10, 60, 90, 180 minutes after (99m)Tc-MDP injection. To determine the amount of activity in each organ, conjugate view method was applied on images. MIRD equation was then used to estimate absorbed doses in different organs of patients. At the end, absorbed dose values obtained in this study were compared with the data of MIRDose software. The absorbed doses per unit of injected activity (mGy/MBq × 10(-4)) for liver, kidneys, bladder wall and spleen were 3.86 ± 1.1, 38.73 ± 4.7, 4.16 ± 1.8 and 3.91 ± 1.3, respectively. The results of this study may be useful to estimate the amount of activity that can be administered to the patient and also showed that methods used in the study for absorbed dose calculation is in good agreement with the data of MIRDose software and it is possible to use by a clinician.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating the Absorbed Dose of Organs in Pediatric Imaging of 99mTc-DTPA Radiopharmaceutical using MIRDOSE Software

Introduction: In this study, organ radiation doses were calculated for the renal agent 99mTc-DTPA in children. Bio-kinetic energy of 99mTc-DTPA was evaluated by scintigraphy and estimates for absorbed radiation dose were provided using standard medical internal radiation dosimetry (MIRD) techniques.Material and Methods: In this applied research, fourteen children patients (6 males and 8 females...

متن کامل

تخمین دوز جذبی ناشی از رادیوداروی 99mTc-DMSA در بیماران کودک تحت اسکن کلیه با استفاده از نرم‌افزار MIRDose و با بکارگیری روش ترکیبی پلنار SPECT

Introduction: 99mTc–Dimercaptosuccinic Acid (DMSA) as evaluation of pediatric genitourinary abnormalities has an important role in pediatric nuclear medicine. The aim of this study was to estimate organs absorbed dose for children injected by 99mTc DMSA using MIRDOSE software and hybrid planar/SPECT method. Methods: After injection of 99mTc-DMSA, ten children with genitourinary abnorma...

متن کامل

اندازه‌گیری دوز جذبی کلیه‌ها، کبد، مثانه و تخمدان در آزمایش سنتی گرافی کلیه با رادیو داروهای 99mTc-EC و 99mTc-DTPA با استفاده از فنتوم به روش دوزیمتری ترمولومینسانس

    Background: In this survey the absorbed dose by kidneys, bladder, liver and ovaries with 99mTc-EC (99mTc Ethylene dicysteine) renal scintigraphy was measured and compared with the absorbed dose from 99mTc-DTPA (99mTc - Dietheylne Triamine Penta-Acid), which often is used in renal scintigraphy.Methods: In this applicable study, we used a water phantom with geometrical sizes similar to that o...

متن کامل

برآورد دوز جذبی ارگان های بدن ناشی از رادیوداروی 99mTc –MDP در بیماران تحت اسکن استخوان به روش دزیمتری اختصاصی و با بکارگیری روش ترکیبی پلنار/SPECT

Introduction: Bone scan is a nuclear medicine scan test, which leads to finding specific abnormalities in the bone. Methylene Diphosphonate (MDP) is used to bone scan. This combination is absorbed by bone tissue and is excreted by the kidneys and bladder. The purpose of this study was to estimate the absorbed dose of organs in bone scan with injection MDP radiopharmaceutical using Mirdose softw...

متن کامل

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012