Punching Glass: A 10-Year Consecutive Series

نویسندگان

  • Nathan Schaefer
  • Julie Cappello
  • Peter O’Donohue
  • Alfred Phillips
  • Devlin Elliott
  • Luca Daniele
چکیده

INTRODUCTION Punching glass can cause severe and debilitating injuries. The literature is scant in regards to the injury patterns, optimal management, and preventative strategies. We have reviewed our experience of these injuries at a regional Australian hospital. METHODS A retrospective chart review of all patients who had punched glass and presented to Cairns Base Hospital between January 2003 and December 2012. Data collected included age, gender, marital status, employment status, alcohol consumption, side of injury, intent, time of presentation, damaged structures, treatment required, operative time, total hospital stay, and required follow-up. RESULTS 137 eligible patients were identified during the 10-year study period. Mean age was 26.3 years. Most were men (n = 113), single (n = 122), unemployed (n = 95), and intoxicated (n = 91). Most of these injuries presented outside of normal working hours (P < 0.001). Ninety-one patients had superficial skin lacerations only and did not require operative intervention. The remaining 46 patients had a total of 46 tendon, 18 muscle, 12 nerve, 8 vessel and 5 bone injuries, and all required operative intervention. Tendon, nerve and vessel injuries were strongly associated with each other (P < 0.05). CONCLUSIONS This represents the largest case series of glass punching injuries in the English literature. Punching glass can cause significant morbidity in a young age group and is therefore a major public health concern. Thorough physical examination, appropriate imaging and operative repair can improve outcomes. Preventative measures such as stricter legislation and safety glass will reduce the burden of these injures on the individual and healthcare system in Australia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Modeling of GFRP-Reinforced Concrete Interior Slab-Column Connections Subjected to Moment Transfer

A finite element model (FEM) was constructed using specialized three-dimensional (3D) software to investigate the punching shear behavior of interior slab-column connections subjected to a moment-to-shear ratio of 0.15 m. The FEM was then verified against the experimental results of full-scale interior slab-column connections reinforced with glass fiber reinforcement polymer (GFRP) bars previou...

متن کامل

Flexural Behavior of Needle Punch Glass/jute Hybrid Mat Composites

In this research, creation of higher mechanical natural fiber mat composites was proposed. The hybrid mat with jute and glass mat was fabricated by needle punching system, in which jute mat was placed on glass mat. The ratio of jute and glass mat layers was set to be 1:0,1:1,1:2 and 2:1, respectively. The composites were fabricated by hand-lay up method with unsaturated polyester resin after ne...

متن کامل

Numerical Simulation of Punching Shear of Flat Plates with Low Reinforcement

Abstract—Punching shear failure is usually the governing failure mode of flat plate structures. Punching failure is brittle in nature which induces more vulnerability to this type of structure. In the present study, a 3D finite element model of a flat plate with low reinforcement ratio and without any transverse reinforcement has been developed. Punching shear stress and the deflection data wer...

متن کامل

A Case with Dopamine-Antagonist Responsive Repetitive Head Punching as Rhythmic Movement Disorder during Sleep

We reported a 17-year-ole male presented with repetitive head punching as rhythmic movement during sleep. Rhythmic movement disorder (RMD) during sleep refers to a number of activities characterized by repetitive stereotyped movements such as rhythmic oscillations of the head, limbs, or body. The repetitive movement like punching on the head in our case is a rare form. The patient's symptom was...

متن کامل

Strength of Footing with Punching Shear Preventers

The punching shear failure often governs the strength of the footing-to-column connection. The punching shear failure is an undesirable failure mode, since it results in a brittle failure of the footing. In this study, a new method to increase the strength and ductility of the footing was proposed by inserting the punching shear preventers (PSPs) into the footing. The validation and effectivene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015