A SURF beamline for synchrotron source-based absolute radiometry

نویسندگان

  • Ping-Shine Shaw
  • Uwe Arp
  • Howard W Yoon
  • Robert D Saunders
  • Albert C Parr
  • Keith R Lykke
چکیده

A new source-based radiometry beamline was recently constructed at the Synchrotron Ultraviolet Radiation Facility (SURF III). The goal of this beamline is to establish a national source standard with a wide spectral range from the far ultraviolet to the infrared by using the calculability of SURF III. The new beamline is a straight-through white-light beamline with few, if any, optical components involved in delivering the radiation to the user end-station for applications such as source and irradiance intercomparisons. Due to the low tunable operating electron energy of SURF III (from 380 MeV to less than 100 MeV), the beamline is uniquely suited to work in the ultraviolet to infrared spectral range. In this paper we discuss the design of the beamline and present first results on the vertical angular distribution of the radiation determined with filtered radiometers in the ultraviolet, visible and near-infrared spectral ranges.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AI-BL1.0: a program for automatic on-line beamline optimization using the evolutionary algorithm.

In this report, AI-BL1.0, an open-source Labview-based program for automatic on-line beamline optimization, is presented. The optimization algorithms used in the program are Genetic Algorithm and Differential Evolution. Efficiency was improved by use of a strategy known as Observer Mode for Evolutionary Algorithm. The program was constructed and validated at the XAFCA beamline of the Singapore ...

متن کامل

Ultraviolet radiometry with synchrotron radiation and cryogenic radiometry.

The combination of a cryogenic radiometer and synchrotron radiation enables detector scale realization in spectral regions that are otherwise difficult to access. Cryogenic radiometry is the most accurate primary detector-based standard available to date, and synchrotron radiation gives a unique broadband and continuous spectrum that extends from x ray to far IR. We describe a new cryogenic rad...

متن کامل

Design, development and first experiments on the X-ray imaging beamline at Indus-2 synchrotron source RRCAT, India.

A full-field hard X-ray imaging beamline (BL-4) was designed, developed, installed and commissioned recently at the Indus-2 synchrotron radiation source at RRCAT, Indore, India. The bending-magnet beamline is operated in monochromatic and white beam mode. A variety of imaging techniques are implemented such as high-resolution radiography, propagation- and analyzer-based phase contrast imaging, ...

متن کامل

خطوط باریکه چشمه نور ایران

This paper describes day-one beamlines of the Iranian Light Source Facility and design concept of powder diffraction and spectromicroscopy beamlines as the most priorities of each synchrotron that cover the research requirements in the fields of physics, chemistry, nano-science, etc. For powder diffraction beamline energy range is 6-30 keV, resolution: 10-4, flux: 1012(ph/s/0.1%B.W.) and spot s...

متن کامل

Spatial resolution limits for synchrotron-based spectromicroscopy in the mid- and near-infrared.

Spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source in Berkeley, CA, USA, a third-generation synchrotron light source. This beamline couples the high-brightness synchrotron source to a Thermo-Electron Continumicrom XL infrared microscope. Two types of resolution tests were performed in both the mid-IR and near-IR. The results are compared with a diffraction-li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003