Extended hierarchical Bayesian diffuse optical tomography for removing scalp artifact.
نویسندگان
چکیده
Functional near-infrared spectroscopy (fNIRS) can non-invasively measure hemodynamic responses in the cerebral cortex with a portable apparatus. However, the observation signal in fNIRS measurements is contaminated by the artifact signal from the hemodynamic response in the scalp. In this paper, we propose a method to separate the signals from the cortex and the scalp by estimating both hemodynamic changes by diffuse optical tomography (DOT). In the inverse problem of DOT, we introduce smooth regularization to the hemodynamic change in the scalp and sparse regularization to that in the cortex based on the nature of the hemodynamic responses. These appropriate regularization models, with the spatial information of optical paths of many measurement channels, allow three-dimensional reconstruction of both hemodynamic changes. We validate our proposed method through two-layer phantom experiments and MRI-based head-model simulations. In both experiments, the proposed method simultaneously estimates the superficial smooth activity in the scalp area and the deep localized activity in the cortical area.
منابع مشابه
Multi-subject and multi-task experimental validation of the hierarchical Bayesian diffuse optical tomography algorithm
Diffuse optical tomography (DOT) is an emerging technology for improving the spatial resolution and spatial specificity of conventional multi-channel near-infrared spectroscopy (NIRS) by the use of high-density measurements and an image reconstruction algorithm. We recently proposed a hierarchical Bayesian DOT algorithm that allows for accurate simultaneous reconstruction of scalp and cortical ...
متن کاملHierarchical Bayesian regularization of reconstructions for diffuse optical tomography using multiple priors
Diffuse optical tomography (DOT) is a non-invasive brain imaging technique that uses low-levels of near-infrared light to measure optical absorption changes due to regional blood flow and blood oxygen saturation in the brain. By arranging light sources and detectors in a grid over the surface of the scalp, DOT studies attempt to spatially localize changes in oxy- and deoxy-hemoglobin in the bra...
متن کاملDiffuse optical tomography with a priori anatomical information.
Diffuse optical tomography (DOT) poses a typical ill-posed inverse problem with a limited number of measurements and inherently low spatial resolution. In this paper, we propose a hierarchical Bayesian approach to improve spatial resolution and quantitative accuracy by using a priori information provided by a secondary high resolution anatomical imaging modality, such as magnetic resonance (MR)...
متن کاملReview of recent progress toward a fiberless, whole-scalp diffuse optical tomography system.
The development of a whole-scalp, high sampling-density diffuse optical tomography (DOT) system is a critical next step in the evolution of the field of diffuse optics. To achieve this with optical fiber bundles is extremely challenging, simply because of the sheer number of bundles required, and the associated challenges of weight and ergonomics. Dispensing with optical fiber bundles and movin...
متن کاملInvestigating hemodynamics in scalp and brain using high- resolution diffuse optical tomography in humans
We investigate prerequisites for developing a continuous wave NIRS bedside brain perfusion monitor. Based on the separation of superficial and cortical layers using 3D HR-DOT we investigate the power and distribution of low frequency oscillations in the brain and scalp. © 2012 Optical Society of America OCIS: (170.6960) Tomography; (170.2655) Functional monitoring and imaging
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical optics express
دوره 4 11 شماره
صفحات -
تاریخ انتشار 2013