Non-constrictive bead immobilization leading to decreased and uniform shear stress in microfluidic bead-based ELISA

نویسندگان

  • Kinshuk Mitra
  • Brett C. Geiger
  • Preethi Chidambaram
  • Aaron P. Maharry
  • Ronald X. Xu
  • Michael F. Tweedle
چکیده

Non-constrictive bead immobilization leading to decreased and uniform shear stress in microfluidic bead-based ELISA K. Mitra, B. Geiger, P. Chidambaram, A. Maharry, R. Xu, M. Tweedle The Ohio State University Department of Biomedical Engineering The Ohio State University Department of Electrical and Computer Engineering The Ohio State University Department of Radiology Present address Rice University Department of Bioengineering

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bead mediated separation of microparticles in droplets

Exchange of components such as particles and cells in droplets is important and highly desired in droplet microfluidic assays, and many current technologies use electrical or magnetic fields to accomplish this process. Bead-based microfluidic techniques offer an alternative approach that uses the bead's solid surface to immobilize targets like particles or biological material. In this paper, we...

متن کامل

Automated microfluidic platform of bead-based electrochemical immunosensor integrated with bioreactor for continual monitoring of cell secreted biomarkers.

There is an increasing interest in developing microfluidic bioreactors and organs-on-a-chip platforms combined with sensing capabilities for continual monitoring of cell-secreted biomarkers. Conventional approaches such as ELISA and mass spectroscopy cannot satisfy the needs of continual monitoring as they are labor-intensive and not easily integrable with low-volume bioreactors. This paper rep...

متن کامل

Textural and Structural Characterizations of Mesoporous Chitosan Beads for Immobilization of Alpha-Amylase: Diffusivity and Sustainability of Biocatalyst

In the present study, textural and structural characterizations of chitosan bead for immobilization of alpha amylase were studied in detail by N2 adsorption–desorption, Microspore Analysis (MP), Barrett–Joyner–Halenda (BJH) plots and Field Emission Scanning Electron Microscope (FESEM) observations. Pore structure observation revealed chemical activation of chitosan bead by glutaralde...

متن کامل

A novel bead-based assay to detect specific antibody responses against Toxoplasma gondii and Trichinella spiralis simultaneously in sera of experimentally infected swine

BACKGROUND A novel, bead-based flow cytometric assay was developed for simultaneous determination of antibody responses against Toxoplasma gondii and Trichinella spiralis in pig serum. This high throughput screening assay could be an alternative for well known indirect tests like ELISA. One of the advantages of a bead-based assay over ELISA is the possibility to determine multiple specific anti...

متن کامل

Increasing the Sensitivity of ELISA using Multiplexed Electrokinetic Concentrator

We developed a novel method to increase the sensitivity of standard Enzyme-Linked Immunosorbent Assay (ELISA) using a multiplexed electrokinetic concentration chip. The poly(dimethylsiloxane) (PDMS) molecular concentrator1 was used to trap and collect charged fluorescent product of targetbound enzyme turnover reaction of ELISA that occurred in a standard 96 well plate. Detection sensitivities o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014