چکیده
OBJECTIVES In this prospective preclinical study, we evaluated T1-weighted signal intensity in the deep cerebellar nuclei (CN) and globus pallidus (GP) up to 24 days after repeated administration of linear and macrocyclic gadolinium-based contrast agents (GBCAs) using homologous imaging and evaluation methods as in the recently published retrospective clinical studies. In a second part of the study, cerebrospinal fluid (CSF) spaces were evaluated for contrast enhancement by fluid-attenuated magnetic resonance imaging (MRI). MATERIALS AND METHODS Sixty adult male Wistar-Han rats were randomly divided into a control and 5 GBCA groups (n = 10 per group). The administered GBCAs were gadodiamide, gadopentetate dimeglumine, and gadobenate dimeglumine (linear GBCAs) as well as gadobutrol and gadoterate meglumine (macrocyclic GBCAs) and saline (control). Over a period of 2 weeks, the animals received 10 intravenous injections at a dose of 2.5 mmol Gd/kg body weight, each on 5 consecutive days per week. Before GBCA administration, as well as 3 and 24 days after the last injection, a whole-brain MRI was performed using a standard T1-weighted 3-dimensional turbo spin echo sequence on a clinical 1.5 T scanner. The ratios of signal intensities in deep CN to pons (CN/Po) and GP to thalamus (GP/Th) were determined. For the evaluation of the CSF spaces, 18 additional rats were randomly divided into 6 groups (n = 3 per group) that received the same GBCAs as in the first part of the study. After MR cisternography for anatomical reference, a fluid-attenuated inversion recovery sequence was performed before and 1 minute after intravenous injection of a dose of 1 mmol Gd/kg body weight GBCA or saline. RESULTS A significantly increased signal intensity ratio of CN/Po was observed 3 and 24 days after the last injection of gadodiamide and gadobenate dimeglumine. No significant changes were observed between the 2 time points. Gadopentetate dimeglumine injection led to a moderately elevated but statistically not significant CN/Po signal intensity ratio. No increased CN/Po signal intensity ratios were determined in the MRI scans of rats that received macrocyclic GBCAs gadobutrol and gadoterate meglumine or saline. The ratio of signal intensity in GP/Th was not elevated in any group injected with GBCAs or saline. Enhanced signal intensities of CSF spaces were observed in the postcontrast fluid-attenuated inversion recovery images of all animals receiving GBCAs but not for saline. CONCLUSIONS In this animal study in rats, increased signal intensity in the CN was found up to 24 days after multiple, extended doses of linear GBCAs. However, in contrast to clinical reports, the signal enhancement in the GP was not reproduced, demonstrating the limitations of this animal experiment. The elevated signal intensities remained persistent over the entire observation period. In contrast, no changes of signal intensities in either the CN or the GP were observed for macrocyclic GBCAs. However, all GBCAs investigated were able to pass the blood-CSF barrier in rats to a certain, not yet quantified extent.
منابع مشابه
Signal Increase on Unenhanced T1-Weighted Images in the Rat Brain After Repeated, Extended Doses of Gadolinium-Based Contrast Agents
Objectives: In this prospective preclinical study, we evaluated T1-weighted signal intensity in the deep cerebellar nuclei (CN) and globus pallidus (GP) up to 24 days after repeated administration of linear and macrocyclic gadoliniumbased contrast agents (GBCAs) using homologous imaging and evaluation methods as in the recently published retrospective clinical studies. In a second part of the s...
متن کاملThe presence of the gadolinium-based contrast agent depositions in the brain and symptoms of gadolinium neurotoxicity - A systematic review
BACKGROUND AND PURPOSE Gadolinium based contrast agents (GBCAs) are widely used in magnetic resonance imaging, but recently, high signal intensity in the cerebellum structures was reported after repeated administrations of contrast- enhanced magnetic resonance images. The aim of this systematic review was to investigate the association between increased signal intensity in the dentate nucleus a...
متن کاملHigh signal intensity in dentate nucleus and globus pallidus on unenhanced T1‐weighted MR images in three patients with impaired renal function and vascular calcification
Gadolinium-based contrast agents (primarily those with linear chelates) are associated with a dose-dependent signal hyperintensity in the dentate nucleus and the globus pallidus on unenhanced T1-weighted MRI following administration to selected patients with normal renal function. The accumulation of gadolinium has also been reported in the skin, heart, liver, lung, and kidney of patients with ...
متن کاملLack of increased signal intensity in the dentate nucleus after repeated administration of a macrocyclic contrast agent in multiple sclerosis
Recently, several studies reported increased signal intensity (SI) in the dentate nucleus (DN) after repeated application of gadolinium-based contrast agents (GBCAs), suggesting a deposition of gadolinium in this location. Patients with relapsing-remitting multiple sclerosis (RRMS) frequently show increased permeability of the blood-brain barrier as part of the inflammatory process in the brain...
متن کاملPediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast Agent.
BACKGROUND AND PURPOSE While there have been recent reports of brain retention of gadolinium following gadolinium-based contrast agent administration in adults, a retrospective series of pediatric patients has not previously been reported, to our knowledge. We investigated the relationship between the number of prior gadolinium-based contrast agent doses and increasing T1 signal in the dentate ...