Interstudy reproducibility of quantitative perfusion cardiovascular magnetic resonance.
نویسندگان
چکیده
PURPOSE To determine the interstudy reproducibility of quantitative first-pass perfusion cardiovascular magnetic resonance with comparison of 2 previously described analysis techniques. There is no published data on the interstudy reproducibility of perfusion cardiovascular magnetic resonance which can be used to determine the significance of longitudinal changes in myocardial perfusion after pharmacologic or therapeutic interventions with defined sample sizes. METHODS Sixteen subjects (7 normal volunteers, 9 patients with coronary artery disease) had rest and adenosine stress perfusion cardiovascular magnetic resonance studies on two separate visits. A short axis slice was studied on each visit using a fast low-angle shot sequence. The global and regional myocardial perfusion reserve indices were calculated using 2 methods: model based constrained deconvolution with the Fermi function, and normalized upslopes. Reproducibility was defined as the standard deviation of the measurement differences, divided by the mean (coefficient of variation). RESULTS The reproducibility of global myocardial perfusion reserve indices was 21% in normal volunteers, which was similar to that in patients with coronary artery disease (CAD) (23%, p = .88). The reproducibility of regional myocardial perfusion reserve indices was 28% (p = .45 vs. global analysis). The reproducibility of global MPRi was superior with Fermi deconvolution compared with normalized upslopes (21% vs. 41%, p = .02). CONCLUSION At this stage of clinical development, the reproducibility of quantitative perfusion cardiovascular magnetic resonance is good, and superior using Fermi deconvolution in preference to upslope analysis.
منابع مشابه
Multi-center transferability of a breath-hold T2 technique for myocardial iron assessment
BACKGROUND Cardiac iron overload is the leading cause of death in thalassemia major and is usually assessed using myocardial T2* measurements. Recently a cardiovascular magnetic resonance (CMR) breath-hold T2 sequence has been developed as a possible alternative. This cardiac T2 technique has good interstudy reproducibility, but its transferability to different centres has not yet been investig...
متن کاملCorrection: reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy
BACKGROUND Myocardial disarray is an important histological feature of hypertrophic cardiomyopathy (HCM) which has been studied post-mortem, but its in-vivo prevalence and extent is unknown. Cardiac Diffusion Tensor Imaging (cDTI) provides information on mean intravoxel myocyte orientation and potentially myocardial disarray. Recent technical advances have improved in-vivo cDTI, and the aim of ...
متن کاملQuantitative cardiovascular magnetic resonance perfusion imaging: inter-study reproducibility.
AIMS To evaluate the inter-study reproducibility of quantitative cardiovascular magnetic resonance (CMR) myocardial perfusion imaging and the influence of diurnal variation on perfusion. Data on these are limited, despite being crucially important for performing serial examinations both in clinical practice and in trials. METHODS AND RESULTS Sixteen healthy volunteers underwent high-resolutio...
متن کاملCardiovascular magnetic resonance: interstudy reproducibility of measurements of left ventricular function in children
Methods CMR was performed in 10 healthy children aged 9 years as part of a study of developmental influences on cardiovascular structure and function. Contiguous short axis steady state free precession LV cine images were acquired. Scans were repeated following a short interval. Interstudy variability was assessed on datasets analysed using a manual post processing technique (Osirix). Each data...
متن کاملInterstudy reproducibility of three-dimensional volume-selective fast spin echo magnetic resonance for quantifying carotid artery wall volume.
PURPOSE To assess the interstudy reproducibility of a three-dimensional volume-selective, fast spin echo (FSE) magnetic resonance technique for the assessment of carotid artery wall volume, which is a marker for total carotid plaque volume. MATERIALS AND METHODS Interstudy reproducibility was evaluated in 10 subjects with evidence of carotid artery atherosclerotic disease on carotid Doppler u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2005