Total thyroidectomy: Conventional Suture Ligation technique versus sutureless techniques using Harmonic Scalpel or Maxium

نویسندگان

  • Jawad Kadhim S. Al-Dhahiry
  • Husam Majeed Hameed
چکیده

OBJECTIVES Harmonic Scalpel (HS) and Maxium (MAX) are surgical shears that enable simultaneous vessel sealing and tissue coagulation. This study compares the outcome of Total Thyroidectomy (TT) using Conventional Suture Ligation (CSL) technique versus (vs) two sutureless techniques; H S and MAX techniques in terms of safety, operative time, blood drainage volume, hospital stay and surgical complications. STUDY DESIGN This is a prospective observational cohort study. SETTING This study was performed in AL-Karama Teaching Hospital/College of Medicine/University of Wasit/Iraq. PATIENTS AND METHODS This study was performed from June 2012 to 2015. A total of 80 patients, 60 patients were females and 20 patients were males (average/mean of age was 39/38 years). They underwent TT after been randomized into the following three groups: CSL group when Suture Ligation Technique was used, HS group when Harmonic Scalpel was used and MAX group when bipolar electrosurgery Maxium was used. RESULTS The postoperative evaluation of operative time, blood drainage volume and surgical complications revealed no statistically significant differences between HS group & MAX group, but there were statistically significant differences between CSL group vs. HS and MAX groups. Operative time statistics showed significant differences between CSL vs. HS and MAX groups, 113 ± 10.9 minutes (min), 93 ± 13 min and 92 ± 10.6 min respectively, p-value < 0.001 and 95% confidence interval [CI] (92.3712, 101.6288). The postoperative blood drainage volumes were significantly different between the three groups: CSL group = 150 ± 12.7 ml, HS group = 89 ± 16.21 ml and MAX group = 118 ± 9.6 ml, P-value = 0.046 and 95% [CI] (89.9932, 99.6068). CONCLUSIONS HS and MAX are safe, effective, and time-saving techniques. They are also associated with low blood loss and low complication rates. HS and MAX are good alternative techniques to CSL for thyroid surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sutureless total thyroidectomy: a safe and cost-effective alternative.

BACKGROUND Advanced vessel sealing devices provide an alternative to conventional ligation techniques for thyroidectomy. To date, most studies have been inadequately powered to explore differences in the infrequent post-operative complications following thyroidectomy. This study is designed to compare the outcomes of sutureless thyroidectomy and conventional thyroidectomy for recurrent laryngea...

متن کامل

The use of FOCUS Harmonic scalpel compared to conventional haemostasis (knot and tie ligation) for thyroid surgery: a prospective randomized study

Haemostasis is crucial in thyroid surgery to avoid intraoperative and postoperative complications. In the present study, we evaluated the efficiency and the safety of Harmonic scalpel when compared to conventional suture ligation in open total thyroidectomy. We enrolled 265 patients who underwent total thyroidectomy for multinodular disease since October 2011 up to October 2013. They were rando...

متن کامل

Comparison between Focus Harmonic scalpel and other hemostatic techniques in open thyroidectomy: A systematic review and meta-analysis.

BACKGROUND The purpose of this review was to compare the efficacy and surgical outcomes of total thyroidectomy between the Focus Harmonic scalpel (Ethicon, Cincinnati, OH) and other hemostatic procedures. METHODS An extensive search was conducted using the PubMed and Cochrane databases from January 2008 to October 2014. Operating time, blood loss, pain, complications, and hospital stay were e...

متن کامل

[Hemostatic systems in thyroid surgery and complications].

INTRODUCTION There have been significant technological advances for hemostasis in thyroid surgery, which allow more precise and safer vascular sealing than the traditional bond associated with mono- or bipolar electrocoagulation. OBJECTIVE To compare the complications in total thyroidectomy using traditional techniques (ligation and electrocoagulation, including LigaSure) compared to the excl...

متن کامل

FOCUS harmonic scalpel compared to conventional hemostasis in open total thyroidectomy - a prospective randomized study

BACKGROUND Hemostasis in thyroid surgery is of utmost importance for a successful surgery and an uneventful postoperative course. Our aim was to evaluate the effectiveness of the FOCUS Harmonic Scalpel in patients undergoing open total thyroidectomy. METHODS In this study, 778 patients were randomized into 2 groups based on the surgical technique used: group I comprised the conventional clamp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016