Matching lung volume data sets--a novel approach.

نویسندگان

  • Wolfgang Recheis
  • Markus Straub
  • Jürg Tschirren
  • Dieter zur Nedden
چکیده

There is a significant demand in matching CT datasets of the lung. The increasing number of CT slices per examination due to the higher resolution of modern CT scanners and the need for quantification of the progress of disease and healing processes in follow-up studies. A volunteer's lung was scanned by the means of multidetector CT in two different states of ventilation. The necessary lung structures for the matching procedure like lung surface and branching points were segmented. A thin-plate spline method was used to calculate the matched lung volume. The preliminary results show an average error of 2 voxel, i.e. 2mm. The calculation of the transformation matrix takes about one second on a conventional PC, which is considerably faster than other methods described in literature. The method described may be apt to be introduced in radiological practice when it comes to compare high resolution CT scans in follow-up studies quantitatively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Assisted History Matching Workflow and its Application in a Full Field Reservoir Simulation Model

The significant increase in using reservoir simulation models poses significant challenges in the design and calibration of models. Moreover, conventional model calibration, history matching, is usually performed using a trial and error process of adjusting model parameters until a satisfactory match is obtained. In addition, history matching is an inverse problem, and hence it may have non-uni...

متن کامل

Fractured Reservoirs History Matching based on Proxy Model and Intelligent Optimization Algorithms

   In this paper, a new robust approach based on Least Square Support Vector Machine (LSSVM) as a proxy model is used for an automatic fractured reservoir history matching. The proxy model is made to model the history match objective function (mismatch values) based on the history data of the field. This model is then used to minimize the objective function through Particle Swarm Optimization (...

متن کامل

Assessing breathing motion by shape matching of lung and diaphragm surfaces∗

Studying complex thorax breating motion is an important research topic for accurate fusion of functional and anatomical data, radiotherapy planning or reduction of breathing motion artifacts. We investigate segmented CT lung, airway and diaphragm surfaces at several different breathing states between Functional Residual and Total Lung Capacity. In general, it is hard to robustly derive correspo...

متن کامل

Lung Segmentation in 4D CT Volumes Based on Robust Active Shape Model Matching

Dynamic and longitudinal lung CT imaging produce 4D lung image data sets, enabling applications like radiation treatment planning or assessment of response to treatment of lung diseases. In this paper, we present a 4D lung segmentation method that mutually utilizes all individual CT volumes to derive segmentations for each CT data set. Our approach is based on a 3D robust active shape model and...

متن کامل

Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography

BACKGROUND To determine the optimal approach to delineating patient-specific internal gross target volumes (IGTV) from four-dimensional (4-D) computed tomography (CT) image data sets used in the planning of radiation treatment for lung cancers. METHODS We analyzed 4D-CT image data sets of 27 consecutive patients with non-small-cell lung cancer (stage I: 17, stage III: 10). The IGTV, defined t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 28 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2004