Design and Calibration of a Polychromator for the Thomson Scattering at Wendelstein 7-X

نویسندگان

  • S. Schmuck
  • A. Dinklage
  • R. Fischer
  • J. P. Knauer
  • B. Kurzan
  • H.-D. Murmann
  • E. Pasch
چکیده

On Wendelstein 7-X, electron density and electron temperature profiles are planned to be measured by Thomson scattering. The specific system employs fiber bundles for the scattered light which is detected by means of a five-channel polychromator system. The detection system is assembled and its components are characterized. A calibration technique employing a super-continuum light source is assessed by comparison with a calibration technique using an optical parametric oscillator laser system. The characterization is preparing further diagnostic optimization studies employing a virtual instrument.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Self-calibration Method for the Edge Thomson Scattering Diagnostic in ITER

Calibration of spectral transmissivity of the collection and transmission optics is one of the most crucial issues for the Thomson scattering diagnostic system. Radioactivation of the vacuum vessel in ITER makes it difficult to calibrate spectral transmissivity in areas near the vacuum vessel. By using an additional calibration laser whose wavelength differs from those of the diagnostic laser a...

متن کامل

Conceptual Design of Polychromator for Thomson Scattering System in JT-60SA

Significant loss in transmissivity of the fiber used for the 18 years operations in JT-60U has been discovered: thereby making optimization of the filter configuration in the polychromator in Thomson scattering system for the high performance plasmas in JT-60SA is an essential task. The loss in the optical components induced by radiation from neutrons and γ-rays in particular needs to be examin...

متن کامل

Design study of the divertor Thomson scattering system for JT-60SA

Feasibility study of the divertor Thomson scattering measurement system for JT-60SA is carried out. A case study of different optical configurations reveals that both laser transmission optics and collection optical system are to be embedded in the lower narrow port plug. From the perspective of the laser induced damage threshold, the size and the material for the laser transmission mirror are ...

متن کامل

Calibration of a Thomson scattering diagnostic for fluctuation measurements.

Detailed calibrations of the Madison Symmetric Torus polychromator Thomson scattering system have been made suitable for electron temperature fluctuation measurements. All calibrations have taken place focusing on accuracy, ease of use and repeatability, and in situ measurements wherever possible. Novel calibration processes have been made possible with an insertable integrating sphere (ISIS), ...

متن کامل

Comparative studies to the design of the interferometer at W7-X with respect to technical boundary conditions

For the optimisation of the beam line configuration of the multi-channel interferometer at the Wendelstein 7-X stellarator the probabilistic approach of Bayesian experimental design (BED) is applied. Parameters of physical interest are directly implemented as design criteria. The quality of the design is analysed according to its expected information gain (expected utility) about the parameters...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008