FDG PET imaging in patients with pathologically verified dementia.

نویسندگان

  • J M Hoffman
  • K A Welsh-Bohmer
  • M Hanson
  • B Crain
  • C Hulette
  • N Earl
  • R E Coleman
چکیده

UNLABELLED The purpose of this study was to confirm with pathologic verification 2 beliefs related to Alzheimer's disease (AD): (a) the long-standing impression that bilateral temporo-parietal hypometabolism, as noted on FDG PET imaging, is the metabolic abnormality associated with Alzheimer's disease (AD) and (b) that the sensitivity, specificity, and diagnostic accuracy of the metabolic pattern of bilateral temporo-parietal hypometabolism allows differentiation between other degenerative causes of dementia. METHODS Twenty two individuals (8 women, 14 men) with difficult-to-characterize memory loss or dementia (using standard clinical criteria), and who eventually received pathologic confirmation of diagnosis, were evaluated. FDG PET brain scans were obtained and visually graded by an experienced nuclear medicine physician as to the presence of classic bilateral temporo-parietal hypometabolism as seen in Alzheimer's type dementia. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the metabolic pattern of bilateral temporo-parietal hypometabolism were determined using pathologic diagnosis as the gold standard. RESULTS The clinical diagnosis of possible or probable AD was determined as the primary cause of dementia in 12 patients. The sensitivity and specificity of the clinical diagnosis for probable AD were 63% and 100%, respectively. The sensitivity and specificity of the clinical diagnosis for possible and probable AD were 75% and 100%, respectively. The sensitivity, specificity, and diagnostic accuracy of bilateral temporo-parietal hypometabolism being associated with AD were 93%, 63%, and 82%, respectively. CONCLUSION This study confirms that bilateral temporo-parietal hypometabolism is indeed the classic metabolic abnormality associated with AD. Furthermore, in individuals with dementia whose FDG PET scans indicated a metabolic pattern other than bilateral temporo-parietal hypometabolism, a cause of dementia other than AD should be suspected. These observations may be of clinical importance in differentiating dementia syndromes. The sensitivity, specificity, and diagnostic accuracy of FDG PET are acceptable as tests to be used in the evaluation of dementia and particularly to confirm the clinical suspicion of AD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

Diagnostic performance of 18F-FDG PET-CT in patients presenting with secondary neck nodes from an unknown primary

Introduction: Clinical examination and even anatomical imaging may fail to identify primary site of malignancy in patients presenting with cervical nodal metastasis. 18F-Fluorodeoxyglucose Positron Emission Computed Tomography (18F-FDG PET-CT) is known to overcome the limitations of anatomic imaging. Methods: Sixty-three (63) patient...

متن کامل

FDG-PET improves accuracy in distinguishing frontotemporal dementia and Alzheimer's disease.

Distinguishing Alzheimer's disease (AD) and frontotemporal dementia (FTD) currently relies on a clinical history and examination, but positron emission tomography with [(18)F] fluorodeoxyglucose (FDG-PET) shows different patterns of hypometabolism in these disorders that might aid differential diagnosis. Six dementia experts with variable FDG-PET experience made independent, forced choice, diag...

متن کامل

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a comb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 2000