Micro-PCR Chip NTC-Thermistor Sensor-Calibration System

نویسندگان

  • Chan-Young Park
  • Yu-Seop Kim
  • Hye-Jeong Song
چکیده

In this paper, we implement a Steinhart-Hart calibration-factor value measurement system to obtain accurate temperature measurements of a negative-temperature coefficient thermistor. The thermistor is mounted on a micro-polymerase chain reaction (PCR) chip in a micro-PCR systemthat requires accurate temperature measurement and control. When obtaining the calibration-factor value, it is impossible to accurately measure and control the temperature unless the measured resistance error is set to 1%. Considering this characteristic, we use the sensor of a to-be-calibrated chip to obtain accurate temperature control of a pre-calibrated chip, and we simultaneously measure the resistance value that corresponds to the temperature of the heating pattern of the precalibrated chip.After attaching a thermal pad on the heating pattern of the pre-calibrated micro-PCR chip for heat transfer, we press it as close as possible against the thermal pad on the heating pattern of the to-be-calibrated chip. When the temperature goal is reached in each of the four sections, we measure the resistance value of the to-be-calibrated chip sensor several times in order to obtain their average values. The results obtained show that the temperature error rate was within the tolerance range when the sensor of the tobe-calibrated chip measured the temperature of the heating pattern in the pre-calibrated chip. We obtained three calibration factor values from the four average resistance values. We record the calibration factor values using an electrically erasable programmable read-only memory attached on the chip, and we perform temperature calibration by again reading the calibrated values from the chip. A conventional calibration system using a constant-temperature water tank takes a long time to reach each target temperature section. However, the calibration system proposed in this paper requires a short time to reach each target temperature, and we therefore confirm that the calibration task time is less than that of conventional calibration systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

Thermistor-based breathing sensor for circadian rhythm evaluation.

One of the most frequently used methods to sense breathing pattern is to detect airflow using a nasal thermistor or a thermocouple sensor. Prolonged, minimally intrusive measurement of the breathing pattern is particularly important for polysomnography, sleeping disorders, stress monitoring, biofeedback techniques, and circadian rhythm analysis. Although most applications require only breathing...

متن کامل

Silicon Piezoresistive Six-Degree of Freedom Micro Force-Moment Sensor

In this paper, we describe the design, fabrication and calibration results of a 6-degree of freedom force-moment micro sensing chip utilizing the piezoresistance effect in silicon. The sensing chip is designed to be able to simultaneously detect three components of force and three components of moment in three orthogonal directions. Conventional p-type and four-terminal p-type piezoresistors ha...

متن کامل

On-chip thermal calibration with 8 CB liquid crystal of micro-thermal device.

A temperature sensor integrated on a micro-device for biological experiments requires affordable, rapid and easy thermal calibration. However, such calibration cannot usually be done directly under the microscope, a fact that impedes biological experiments. We present in this paper an inexpensive and rapid method to achieve thermal calibration directly under the microscope. It is based on the u...

متن کامل

A Study of Thermistor Performance within a Textile Structure

Textiles provide an ideal structure for embedding sensors for medical devices. Skin temperature measurement is one area in which a sensor textile could be particularly beneficial; pathological skin is normally very sensitive, making the comfort of anything placed on that skin paramount. Skin temperature is an important parameter to measure for a number of medical applications, including for the...