Three-dimensional ultrasonographic appearance of the fetal akinesia deformation sequence.

نویسندگان

  • Rodrigo Ruano
  • Yves Dumez
  • Marc Dommergues
چکیده

OBJECTIVE To present the appearance of the fetal akinesia deformation sequence by three-dimensional ultrasonography after four-dimensional ultrasonographic scanning. METHODS Three-dimensional surface-rendering images were used to show the fixed postural abnormalities of the fetal extremities and body. Four-dimensional ultrasonography was used to show that the postural abnormalities were fixed and to confirm the absence of fetal movements. These images were compared with the postmortem examination findings. RESULTS Three-dimensional ultrasonographic images of 3 cases of fetal akinesia deformation sequence are presented. Surface-rendering imaging and imaging in the skeletal mode were performed to show the postural abnormalities and the arthrogryposis. CONCLUSIONS Facilitated by polyhydramnios, three- and four-dimensional ultrasonography provided clear images of the fixed postural abnormalities, which were confirmed by postmortem examination. Although prenatal diagnosis can be easily made by conventional ultrasonography, three-dimensional ultrasonography might be used as a confirmatory approach. In addition, the quality of recent three-dimensional imaging might help prenatal counseling by providing images more readily understandable to the parents than those obtained by two-dimensional ultrasonography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fetal akinesia deformation sequence: a case report and review of literature

Fetal Akinesia Deformation Sequence (FADS) is a condition characterised by decreased fetal movement (fetal akinesia), multiple joint contractures (arthrogryposis), facial anomalies, intrauterine growth restriction, pulmonary hypoplasia and other developmental abnormalities. These disorders are clinically and genetically heterogenous and its etiology remains unclear. This syndrome is rare and th...

متن کامل

Three-dimensional ultrasonographic presentation of micrognathia.

OBJECTIVE To present the variable appearance of micrognathia in fetuses by three-dimensional ultrasonography and to describe practical methods for analysis of these volume data. METHODS Three-dimensional multiplanar imaging and surface-rendering techniques were used to show various syndromes and diagnostic approaches for the evaluation of fetal micrognathia. RESULTS Nine cases of fetal micr...

متن کامل

Deficiency of the myogenic factor MyoD causes a perinatally lethal fetal akinesia.

BACKGROUND Lethal fetal akinesia deformation sequence (FADS) describes a clinically and genetically heterogeneous phenotype that includes fetal akinesia, intrauterine growth retardation, arthrogryposis and developmental anomalies. Affected babies die as a result of pulmonary hypoplasia. We aimed to identify the underlying genetic cause of this disorder in a family in which there were three affe...

متن کامل

Early onset asymmetrical intrauterine growth retardation with fetal hypokinesia and variable expression of acral and genitourinary malformations: a new lethal MCA syndrome.

We report four sibs, two males and two females, with severe and early onset asymmetrical intrauterine growth retardation (IUGR) with a disproportionally large head and a fetal akinesia deformation sequence. Neuromuscular studies were normal in the four sibs. Variable acral malformations (bilateral cleft hand in one male, proximal syndactyly of the toes (right II-III; left II-III/IV-V) in the ot...

متن کامل

Three-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs

Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2003