In vivo evaluation of a phosphorylcholine coated cardiopulmonary bypass circuit.

نویسندگان

  • F De Somer
  • Y Van Belleghem
  • L Foubert
  • K François
  • F Dubrulle
  • D De Wolf
  • G Van Nooten
چکیده

A complete phosphorylcholine coated cardiopulmonary bypass circuit, including the Dideco D901 oxygenator, was tested for gas transfer, blood path resistance, and biocompatibility in a standardized setting. Blood compatibility was tested by measuring complement and platelet activation. Three dogs (mean body weight 28 +/- 3 kg) were placed on cardiopulmonary bypass at a flow rate of 600 mL/min during 6 hours. The animals were weaned from cardiopulmonary bypass and sacrificed electively after 7 days. Oxygen and carbon dioxide transfer were 26.6 +/- 2.4 mL/min and 33.0 +/- 1.9 mL/min, respectively. Mean pressure drop across the oxygenator was 52.6 +/- 0.2 mmHg. The respective baseline values for thromboxane B2, prostaglandin E2 and platelet factor 4 were 1817 +/- 283 pg/mL, 12783 +/- 2109 pg/mL, and 0.35 +/- 0.08 IU/mL. Thromboxane B2 and prostaglandin E2 increased slightly to 2881 +/- 868 pg/mL and 18083 +/- 3144 pg/mL at 30 minutes of bypass, whereas platelet factor 4 values remained stable curing the procedure. Concentrations of complement split products C5a were only mildly increased. After use scanning electron microscopy was performed on the inner housing, heat exchanger, and outer surface of the hollow fibers. No thrombi nor organized cellular deposits were found on any of the components. Phosphorylcholine coating of CPB seems to be very promising regarding platelet activation and complement activation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective analysis of outcome data with regards to the use of Phisio®-, Bioline®- or Softline®-coated cardiopulmonary bypass circuits in cardiac surgery.

BACKGROUND Numerous cardiopulmonary bypass circuits with various coatings designed to reduce the inflammatory response and to provide better hemocompatibility are available. The aim of this study was to compare the effect of phosphorylcholine-coated, albumin-heparin-coated and synthetic polymer-coated perfusion tubing systems on patient outcome. METHODS We performed a retrospective database r...

متن کامل

Humoral immune response and coated or uncoated oxygenators during cardiopulmonary bypass surgery

AIM To investigate and compare uncoated and phosphorylcholine-coated oxygenators in terms of induction of humoral immune response during coronary artery bypass surgery. METHODS A total of 20 consecutive patients who underwent coronary artery bypass surgery were randomly distributed into two groups according to the type of oxygenator used during surgery. Group 1 consisted of 10 patients who we...

متن کامل

Evaluation of Mimesys phosphorylcholine (PC)-coated oxygenators during cardiopulmonary bypass in adults.

A new generation of coating extracorporeal circuitry with biocompatible polymers has entered the North American perfusion market. This new biomimetic coating process uses synthetic phosphorylcholine (PC) containing polymers to bond covalently to the surface of the Sorin Monolyth oxygenator, under the brand name of Mimesys. In part one of a three-part investigation, 160 Mimesys-coated oxygenator...

متن کامل

Impact of a phosphorylcholine-coated cardiac bypass circuit on blood loss and platelet function: a prospective, randomized study.

Platelet dysfunction due to cardiopulmonary bypass (CPB) surgery increases the risk of bleeding. This study analyzed the effect of a phosphorylcholine (PC)-coated CPB circuit on blood loss, transfusion needs, and platelet function. We performed a prospective, randomized study at Strasbourg University Hospital, which included 40 adults undergoing coronary artery bypass graft surgery (CABG) (n = ...

متن کامل

Evaluation of the effects of phosphorylcholine coated membrane oxygenators on renal functions in cardiac surgery patients

Objectives: Acute and chronic renal injury has an important effect on the surgical outcome of cardiovascular diseases in terms of morbidity and mortality. The coating techniques which have been significantly improved in the recent years aim to decrease the contact of blood with foreign surfaces in the cardiopulmonary bypass. The aim of this study is to research the effects of phosphorylcholine ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 1999