Detector of Image Orientation Based on Borda-Count

نویسندگان

  • Loris Nanni
  • Alessandra Lumini
چکیده

Accurately and automatically detecting image orientation is a task of great importance in intelligent image processing. In this paper, we present automatic image orientation detection algorithms based on these features: color moments; harris corner; phase symmetry; edge direction histogram. The statistical learning support vector machines, AdaBoost, Subspace classifier are used in our approach as classifiers. We use Borda Count as combination rule for these classifiers. Large amounts of experiments have been conducted, on a database of more than 6,000 images of real photos, to validate our approaches. Discussions and future directions for this work are also addressed at the end of the paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Borda count in n-dimensional issue space

We provide a natural extension of the Borda count to the n-dimensional spatial context, an algorithm to find the spatial Borda winner based on the notion of an inverse Borda count, the result that the Borda winner and the Condorcet winner coincide in unidimensional space when all alternatives on a line are feasible, results that show that in multi-dimensional space the Borda winner and the Cond...

متن کامل

Content Based Radiographic Images Indexing and Retrieval Using Pattern Orientation Histogram

Introduction: Content Based Image Retrieval (CBIR) is a method of image searching and retrieval in a  database. In medical applications, CBIR is a tool used by physicians to compare the previous and current  medical images associated with patients pathological conditions. As the volume of pictorial information  stored in medical image databases is in progress, efficient image indexing and retri...

متن کامل

Optimization of Gate’s technique for measurement of GFR during routine renal scan [Persian]

Using Gate’s technique for GFR measurement with Gamma camera, the patient is received 5mCi of Tc-99m-DTPA. By this amount of radioactivity, good quality renal scan is not possible. This study tries to optimize Gate’s technique for GFR measurement during routine renal scan (with 10-15 mCi). Methods and materials: Scanning was performed for 60 seconds from samples of Tc-99m with activities ...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

A Novel Diffusion Filter for Image Restoration and Enhancement

We are proposing a new filter for image restoration and enhancement tasks that relies on image orientation analysis techniques for steering and directing smoothing or enhancement processes. The filter is developed under the Partial Differential Equations (PDE) framework using asymmetric orientation estimation operators and it has better junction preservation and noise removal properties than ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005