Ground faults in photovoltaic (PV) systems pose a fire and shock hazard. To mitigate these risks, AC-isolated, DC grounded PV systems in the United States use Ground Fault Protection Devices (GFPDs), e.g., fuses, to de-energize the PV system when there is a ground fault. Recently the effectiveness of these protection devices has come under question because multiple fires have started when ground faults went undetected. In order to understand the limitations of fuse-based ground fault protection in PV systems, analytical and numerical simulations of different ground faults were performed. The numerical simulations were conducted with Simulation Program with Integrated Circuit Emphasis (SPICE) using a circuit model of the PV system which included the modules, wiring, switchgear, grounded or ungrounded components, and the inverter. The derivation of the SPICE model and the results of parametric fault current studies are provided with varying array topologies, fuse sizes, and fault impedances. Closed-form analytical approximations for GFPD currents from faults to the grounded current carrying conductor—known as “blind spot” ground faults—are derived to provide greater understanding of the influence of array impedances on fault currents. The behavior of the array during various ground faults is studied for a range of ground fault fuse sizes to determine if reducing the size of the fuse improves ground fault detection sensitivity. The results of the simulations show that reducing the amperage rating of the protective fuse does increase fault current detection sensitivity without increasing the likelihood of nuisance trips to a degree. Unfortunately, this benefit reaches a limit as fuses become smaller and their internal resistance increases to the point of becoming a major element in the fault current circuit.
منابع مشابه
Recommendations for Rcd Ground Fault Detector Trip Thresholds
Photovoltaic (PV) ground faults have caused many fires in the U.S. and around the world. Recently, the American PV industry has discovered a blind spot in fuse-based ground fault detection that has spurred a transition to a number of alternatives traditionally used in European markets. This paper investigates the repeatability of one of these methods, residual current detection (RCD), using his...
متن کاملRecommendations for CSM and Riso Ground Fault Detector Trip Thresholds
PV ground faults have caused many fires in the U.S. and around the world. One cause of these fires is a “blind spot” in the ground fault ground fault fuse.. As a result of this discovery, the Solar America Board for Codes and Standards identified a number of alternatives to ground fault fuses, but these technologies have limited historical use in the United States. This paper investigates the e...
متن کاملApplying Frequency Response method for contact Rails Fault Diagnosing in Ungrounded Electrical Railway System
Abstract General faults in regular electrical railways system could be detect by implementing the specific protection functions such as ground fault or sensitive earth fault. Otherwise, in ungrounded electrical railway systems which using both feeding and return contact rail at the same time, fault detection cannot done with above-mentioned function. Due to recent growth in electrical railway ...
متن کاملInternal Fault Detection, Location, and Classification in Stator Winding of the Synchronous Generators Based on the Terminal Voltage Waveform
In this paper, a novel method is presented for detection and classification of the faultyphase/region in the stator winding of synchronous generators on the basis of the resulting harmoniccomponents that appear in the terminal voltage waveforms. Analytical results obtained through DecisionTree (DT) show that the internal faults are not only detectable but also they can be classified andthe rela...
متن کاملOptimal Reconfiguration of Solar Photovoltaic Arrays Using a Fast Parallelized Particle Swarm Optimization in Confront of Partial Shading
Partial shading reduces the power output of solar modules, generates several peak points in P-V and I-V curves and shortens the expected life cycle of inverters and solar panels. Electrical array reconfiguration of PV arrays that is based on changing the electrical connections with switching devices, can be used as a practical solution to prevent such problems. Valuable studies have been perfor...