Use of rapid HIV assays as supplemental tests in specimens with repeatedly reactive screening immunoassay results not confirmed by HIV-1 Western blot.

نویسندگان

  • Laura G Wesolowski
  • Kevin P Delaney
  • William A Meyer
  • Amy J Blatt
  • Berry Bennett
  • Pollyanna Chavez
  • Timothy C Granade
  • Michele Owen
چکیده

BACKGROUND An alternate HIV testing algorithm has been proposed which includes a fourth-generation immunoassay followed by an HIV-1/HIV-2 antibody differentiation supplemental test for reactive specimens and a nucleic acid test (NAT) for specimens with discordant results. OBJECTIVE To evaluate the performance of five rapid tests (Alere Clearview, Bio-Rad Multispot, OraSure OraQuick, MedMira Reveal, and Trinity Biotech Unigold) as the supplemental antibody assay in the algorithm. STUDY DESIGN A total of 3273 serum and plasma specimens that were third-generation immunoassay repeatedly reactive and Western blot (WB) negative or indeterminate were tested with rapid tests and NAT. Specimens were classified by NAT: (1) HIV-1 infected (NAT-reactive; n=184, 5.6%), (2) HIV-status unknown (NAT nonreactive; n=3078, 94.2%) or by Multispot, (3) HIV-2 positive (n=5), and (4) HIV-1 and HIV-2 positive (n=6). Excluding HIV-2 positive specimens, we calculated the proportion of reactive rapid tests among specimens with reactive and nonreactive NAT. RESULTS The proportion of infected specimens with reactive rapid test results and negative or indeterminate WB ranged from 30.4% (56) to 47.8% (88) depending on the rapid test. From 1% to 2% of NAT-negative specimens had reactive rapid test results. CONCLUSIONS In these diagnostically challenging specimens, all rapid tests identified infections that were missed by the Western blot, but only Multispot could differentiate HIV-1 from HIV-2. Regardless of which rapid test is used as a supplemental test in the alternative algorithm, false-positive algorithm results (i.e., reactive screening and rapid test in uninfected person) may occur, which will need to be resolved during the baseline medical evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HIV Indeterminate Western Blot Results in Blood Donors in Northeast of Iran, 2009-2014

Background and Aims: HIV is spreading rapidly among people word wide. Infection with this virus leads to immune suppression and finally acquired immune deficiency syndrome (AIDS).Early HIV detection is depended on antibody screening against virus by Enzyme Linked Immunosorbent Assay (ELISA).Some confirmatory tests such as Western Blot and Recombinant Immunobloting Assay (RIBA), are used to ve...

متن کامل

Preclinical and clinical performance of the Efoora test, a rapid test for detection of human immunodeficiency virus-specific antibodies.

Barriers to effective diagnostic testing for human immunodeficiency virus type 1 (HIV-1) infection can be reduced with simple, reliable, and rapid detection methods. Our objective was to determine the accuracy, sensitivity, and specificity of a new rapid, lateral-flow immunochromatographic HIV-1 antibody detection device. Preclinical studies were performed using seroconversion, cross-reaction, ...

متن کامل

Evaluation of HIV Indeterminate Confirmatory Tests\' Results in Blood Donors in Northeast of Iran

Background and Aims: Human Immunodeficiency virus (HIV) is spreading rapidly among the people worldwide. Infection with this virus leads to immune suppression and finally acquired immune deficiency syndrome. Early HIV detection is dependent on antibody screening against virus by Enzyme Linked Immunosorbent Assay (ELISA). Some confirmatory tests such as Western Blot and Recombinant Immunobl...

متن کامل

Detection of Acute HIV Infection in Two Evaluations of a New HIV Diagnostic Testing Algorithm — United States, 2011–2013

The highly infectious phase of acute human immunodeficiency virus (HIV) infection, defined as the interval between the appearance of HIV RNA in plasma and the detection of HIV-1-specific antibodies, contributes disproportionately to HIV transmission. The current HIV diagnostic algorithm consists of a repeatedly reactive immunoassay (IA), followed by a supplemental test, such as the Western blot...

متن کامل

An alternative approach to confirming anti-HIV reactivity: a multi-country collaborative study.

The confirmation of positive screening assay reactions for antibodies to human immunodeficiency virus type 1 (anti-HIV-1) by Western blot is expensive and often gives indeterminate results. We therefore carried out a collaborative study to investigate the confirmation of screening assay reactions using a second screening assay. For this purpose, seven laboratories prospectively tested sequentia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2013