Novel sphene coatings on Ti-6Al-4V for orthopedic implants using sol-gel method.

نویسندگان

  • Chengtie Wu
  • Yogambha Ramaswamy
  • David Gale
  • Wenrong Yang
  • Keqin Xiao
  • Liangchi Zhang
  • Yongbai Yin
  • Hala Zreiqat
چکیده

Hydroxyapatite (HAp) is commonly used to coat titanium alloys (Ti-6Al-4V) for orthopedic implants. However, their poor adhesion strength and insufficient long-term stability limit their application. Novel sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study is to use the novel sphene ceramics as coatings for Ti-6Al-4V. The sol-gel method was used to produce the coatings and the thermal properties, phase composition, microstructure, thickness, surface roughness and adhesion strength of sphene coatings were analyzed by differential thermal analysis-thermal gravity (DTA-TG), X-ray diffraction (XRD), scanning electron microscopy (SEM), atom force microscopy (AFM) and scratch test, respectively. DTA analysis confirmed that the temperature of the sphene phase formation is 875 degrees C and XRD analysis indicated pure sphene coatings were obtained. A uniform structure of the sphene coating was found across the Ti-6Al-4V surface, with a thickness and surface roughness of the coating of about 0.5-1 microm and 0.38 microm, respectively. Sphene-coated Ti-6Al-4V possessed a significantly improved adhesion strength compared to that for HAp coating and their chemical stability was evaluated by testing the profile element distribution and the dissolution kinetics of calcium (Ca) ions after soaking the sphene-coated Ti-6Al-4V in Tris-HCl solution. Sphene coatings had a significantly improved chemical stability compared to the HAp coatings. A layer of apatite formed on the sphene-coated Ti-6Al-4V after they were soaked in simulated body fluids (SBF). Our results indicate that sol-gel coating of novel sphene onto Ti-6Al-4V possessed improved adhesion strength and chemical stability, compared to HAp-coated Ti-6Al-4V prepared under the same conditions, suggesting their potential application as coatings for orthopedic implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma-sprayed CaTiSiO5 ceramic coating on Ti-6Al-4V with excellent bonding strength, stability and cellular bioactivity.

Novel Ca-Si-Ti-based sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study was to prepare sphene coating on titanium alloy (Ti-6Al-4V) for orthopaedic applications using the plasma spray method. The phase composition, surface and interface microstructure, coating thickness, surface roughness and bonding strength of the plasma-sprayed sphene...

متن کامل

Comparative investigation on the adhesion of hydroxyapatite coating on Ti–6Al–4V implant_ A review paper

Hydroxyapatite (HA) has been used in clinical bone graft procedures for the past 25 years. Although a biocompatible material, its poor adhesion strength to substrate makes it unsuitable for major loadbearing devices. Investigations on various deposition techniques of HA coating on Ti–6Al–4V implants have been made over the years, in particular to improve its adhesion strength to the metal alloy...

متن کامل

Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy

PURPOSE The purpose of this study was to assess the surface characteristics and the biocompatibility of zirconium (Zr) coating on Ti-6Al-4V alloy surface by radio frequency (RF) magnetron sputtering method. MATERIALS AND METHODS The zirconium films were developed on Ti-6Al-4V discs using RF magnetron sputtering method. Surface profile, surface composition, surface roughness and surface energy...

متن کامل

Effect of Tricalcium Magnesium Silicate Coating on the Electrochemical and Biological Behavior of Ti-6Al-4V Alloys

In the current study, a sol-gel-synthesized tricalcium magnesium silicate powder was coated on Ti-6Al-4V alloys using plasma spray method. Composition of feed powder was evaluated by X-ray diffraction technique before and after the coating process. Scanning electron microscopy and atomic force microscopy were used to study the morphology of coated substrates. The corrosion behaviors of bare and...

متن کامل

Early bone apposition in vivo on plasma-sprayed and electrochemically deposited hydroxyapatite coatings on titanium alloy.

Three different implants, bare Ti-6Al-4V alloy, Ti-6Al-4V alloy coated with plasma-sprayed hydroxyapatite (PSHA), and Ti-6Al-4V alloy coated with electrochemically deposited hydroxyapatite (EDHA), were implanted into canine trabecular bone for 6 h, 7, and 14 days, respectively. Environmental scanning electron microscopy study showed that PSHA coatings had higher bone apposition ratios than thos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta biomaterialia

دوره 4 3  شماره 

صفحات  -

تاریخ انتشار 2008