Timing and Operating Mode Design for Time-Gated Fluorescence Lifetime Imaging Microscopy

نویسندگان

  • Chao Liu
  • Xinwei Wang
  • Yan Zhou
  • Yuliang Liu
چکیده

Steady-state fluorence imaging and time-resolved fluorescence imaging are two important areas in fluorescence imaging research. Fluorescence lifetime imaging is an absolute measurement method which is independent of excitation laser intensity, fluorophore concentration, and photobleaching compared to fluorescence intensity imaging techniques. Time-gated fluorescence lifetime imaging microscopy (FLIM) can provide high resolution and high imaging frame during mature FLIM methods. An abstract time-gated FLIM model was given, and important temporal parameters are shown as well. Aiming at different applications of steady and transient fluorescence processes, two different operation modes, timing and lifetime computing algorithm are designed. High resolution and high frame can be achieved by one-excitation one-sampling mode and least square algorithm for steady imaging applications. Correspondingly, one-excitation two-sampling mode and rapid lifetime determination algorithm contribute to transient fluorescence situations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-domain whole-field fluorescence lifetime imaging with optical sectioning.

A whole-field time-domain fluorescence lifetime imaging (FLIM) microscope with the capability to perform optical sectioning is described. The excitation source is a mode-locked Ti:Sapphire laser that is regeneratively amplified and frequency doubled to 415 nm. Time-gated fluorescence intensity images at increasing delays after excitation are acquired using a gated microchannel plate image inten...

متن کامل

High-speed wide-field time-gated endoscopic fluorescence-lifetime imaging.

We report the development of a high-speed wide-field fluorescence-lifetime imaging (FLIM) system that provides fluorescence-lifetime images at rates of as many as 29 frames/s. A FLIM multiwell plate reader and a potentially portable FLIM endoscopic system operating at 355-nm excitation have been demonstrated.

متن کامل

Enhancing precision in time-domain fluorescence lifetime imaging.

In biological applications of fluorescence lifetime imaging, low signals from samples can be a challenge, causing poor lifetime precision. We demonstrate how optimal signal gating (a method applied to the temporal dimension of a lifetime image) and novel total variation denoising models (a method applied to the spatial dimension of a lifetime image) can be used in time-domain fluorescence lifet...

متن کامل

Intracellular Fluorescence Lifetime Imaging of Ala-ppix Using Ps Diode Lasers and Tcspc Techniques in Laser Scanning Microscopes

A setup consisting on a laser scanning microscope (LSM 410, Zeiss, Germany) equipped with appropriate detection units was developed for time-resolved intracellular fluorescence spectroscopy and fluorescence lifetime imaging (FLIM) for on-line detection of structural changes of various biomolecules. Short-pulsed excitation was performed with a diode laser which emits pulses at 398 nm with 70 ps ...

متن کامل

Time-Correlated Fluorescence Microscopy Using a Room Temperature Solid-State Single Photon Sensor

In this paper we present a two-photon fluorescence lifetime imaging microscopy (FLIM) system based on a two-dimensional single photon avalanche diode (SPAD) array fabricated in CMOS [1] [2]. To the best of our knowledge, this is the first demonstration of two-photon FLIM based on a CMOS detector. The sensor reported here exhibits picosecond accuracy, operates at room temperature, and requires n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013