A Novel Robotic Laser Ablation System for Precision Neurosurgery with Intraoperative 5-ALA-Induced PpIX Fluorescence Detection

نویسندگان

  • Masafumi Noguchi
  • Eisuke Aoki
  • Daiki Yoshida
  • Etsuko Kobayashi
  • Shigeru Omori
  • Yoshihiro Muragaki
  • Hiroshi Iseki
  • Katsushige Nakamura
  • Ichiro Sakuma
چکیده

We developed a combined system of tumor detection by 5-ALA-induced PpIX fluorescence and precise ablation by micro laser for the first time, with an automatic focusing and robotic scanning mechanism for the brain surface. 5-ALA accumulates on tumors to be metabolized to become PpIX that is a fluorescent. Intra-operative detection of 5-ALA induced PpIX fluorescence provides useful information for tumor detection. The wavelength of the micro laser is 2.8 microm close to the absorption band of water. This laser is effective only on the surface of brain tissue, enabling precise ablation at the boundary between tumor and normal tissue identified by intra-operative 5-ALA induced fluorescence. Combination tests of the fluorescence measurement and the laser ablation were performed, and it was possible to extract the area with fluorescence appropriately from the measurement data, and the micro laser with automatically scanning selectively ablated the extracted area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interventional imaging in neurosurgery of gliomas: use of several fluorescence emission spectra of 5-ALA induced protoporphyrin IX to guide neurosurgeons

Gliomas are infiltrative tumors of the central nervous system that account for more than 50 % of primitive brain tumors [1]. Their current treatment is based on surgery when possible but a tradeoff needs to be found by neurosurgeons between removing the maximum amount of tumor cells and preserving functionality of the brain. To help removing the maximum amount of tumor cells, a clear definition...

متن کامل

Multiphoton excitation fluorescence microscopy of 5-aminolevulinic acid induced fluorescence in experimental gliomas.

BACKGROUND AND OBJECTIVE The clinical usefulness of 5-ALA guided detection of tumor tissue has been demonstrated for a number of malignancies. However, current techniques of intraoperative detection of protoporphyrin IX fluorescence in situ do not offer subcellular resolution. Therefore, discrimination of non-specific 5-ALA induced fluorescence remains difficult. MATERIALS AND METHODS In this...

متن کامل

Simplified and optimized multispectral imaging for 5-ALA-based fluorescence diagnosis of malignant lesions

5-aminolevulinic acid (5-ALA)-based fluorescence diagnosis is now clinically applied for accurate and ultrarapid diagnosis of malignant lesions such as lymph node metastasis during surgery. 5-ALA-based diagnosis evaluates fluorescence intensity of a fluorescent metabolite of 5-ALA, protoporphyrin IX (PPIX); however, the fluorescence of PPIX is often affected by autofluorescence of tissue chromo...

متن کامل

A Study on the Photobleaching Effect of 5-ALA Conjugated Gold Nanoparticles in a CT26 Tumor Model During Photodynamic Therapy

Introduction During the process photodynamic therapy (PDT), bleaching of photosensitizer induced by irradiation and generation of reactive oxygen species (ROS) can provide some information concerning the efficiency of treatment. Since gold nanoparticles (GNPs) have been highlighted as efficient drug delivery systems, in this study, by utilizing GNPs conjugated with 5 aminolevulinic acid (5-ALA-...

متن کامل

بررسی مقایسه‌ای دوزیمتری PpIX تولید شده درون تومور پس از مصرف ALA در درمان فوتوداینامیک به دو روش فلوئوریمتری و فلوئورسانس اسپکتروسکوپی

    Background: The important issue in the application of Photodynamic Therapy (PDT), as one of the fundamental basis of new treatment for cancerous lesions, is optimal dosimetry. In this context, it is necessary to obtain enough information about the drug concentration within the target tissue. On the other hand, the fact that ALA itself is not a photosensitizer and causes the production of Pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 9 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2006