A new method for noninvasive venous blood oxygen detection

نویسندگان

  • Xu Zhang
  • Meimei Zhang
  • Shengkun Zheng
  • Liqi Wang
  • Jilun Ye
چکیده

BACKGROUND Blood oxygen saturation of vein (SvO2) is an important clinical parameter for patient monitoring. However, the existing clinical methods are invasive, expensive, which are also painful for patients. METHODS Based on light-absorption, this study describes a new noninvasive SvO2 measurement method by using external stimulation signal to generate cyclical fluctuation signal in the vein, which overcomes the low signal-to-noise ratio problem in the measurement process. In this way, the value of SvO2 can be obtained continuously in real time. RESULTS The experimental results demonstrate that the method can successfully measure venous oxygen saturation by artificial addition of stimulation. Under hypoxic conditions, the system can reflect the overall decline of venous oxygen saturation better. When the results measured by the new method are compared with those measured by the invasive method, the root mean square error of the difference is 5.31 and the correlation coefficient of the difference is 0.72. The new method can be used to measure SvO2 and evaluate body oxygen consumption, and its accuracy needs improvement. CONCLUSIONS Real-time and continuous monitoring can be achieved by replacing invasive method with noninvasive method, which provides more comprehensive clinical information in a timely manner and better meet the needs of clinical treatment. However, the accuracy of the new noninvasive SvO2 measurement based on light-absorption has to be further improved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content

Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...

متن کامل

A study on new method of noninvasive esophageal venous pressure measurement based on the airflow and laser detection technology.

Using optics combined with automatic control and computer real-time image detection technology, a novel noninvasive method of noncontact pressure manometry was developed based on the airflow and laser detection technology in this study. The new esophageal venous pressure measurement system was tested in-vitro experiments. A stable and adjustable pulse stream was produced from a self-developed p...

متن کامل

Diminished visibility of cerebral venous vasculature in multiple sclerosis by susceptibility-weighted imaging at 3.0 Tesla.

Multiple sclerosis (MS) is a disease of the central nervous system characterized by widespread demyelination, axonal loss and gliosis, and neurodegeneration; susceptibility-weighted imaging (SWI), through the use of phase information to enhance local susceptibility or T2* contrast, is a relatively new and simple MRI application that can directly image cerebral veins by exploiting venous blood o...

متن کامل

MRI estimation of global brain oxygen consumption rate.

Measuring the global cerebral metabolic rate of oxygen (CMRO(2)) is a valuable tool for assessing brain vitality and function. Measurement of blood oxygen saturation (HbO(2)) and flow in the major cerebral outflow and inflow vessels can provide a global estimate of CMRO(2). We demonstrate a rapid noninvasive method for quantifying CMRO(2) by simultaneously measuring venous oxygen saturation in ...

متن کامل

Physiologic and Clinical Principles behind Noninvasive Resuscitation Techniques and Cardiac Output Monitoring

Clinical assessment and vital signs are poor predictors of the overall hemodynamic state. Optimal measurement of the response to fluid resuscitation and hemodynamics has previously required invasive measurement with radial and pulmonary artery catheterization. Newer noninvasive resuscitation technology offers the hope of more accurately and safely monitoring a broader range of critically ill pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2016