Automatic Identification and Removal of Ocular Artifacts from EEG using Wavelet Transform

نویسندگان

  • V. Krishnaveni
  • S. Jayaraman
  • S. Aravind
  • V. Hariharasudhan
  • K. Ramadoss
چکیده

The Electroencephalogram (EEG) is a biological signal that represents the electrical activity of the brain. Eye-blinks and movement of the eyeballs produce electrical signals that are collectively known as Ocular Artifacts (OA). These are of the order of milli-volts and they contaminate the EEG signals which are of the order of micro-volts. The frequency range of EEG signal is 0 to 64 Hz and the OA occur within the range of 0 to 16 Hz. If the wavelet based EOG correction algorithm is applied to the entire length of the EEG signal, it results in thresholding of both low frequency and high frequency components even in the non-OA zones. This leads to considerable loss of valuable background EEG activity. Though the detection of OA zones can be done by visual inspection, the OA time zones need to be given as input to the EOG correction procedure, which is a laborious process. Hence there is a need for automatic detection of artifact zones. This paper discusses a method to automatically identify slow varying OA zones and applying wavelet based adaptive thresholding algorithm only to the identified OA zones, which avoids the removal of background EEG information. Adaptive thresholding applied only to the OA zone does not affect the low frequency components in the non-OA zones and also preserves the shape (waveform) of the EEG signal in nonartifact zones which is of very much importance in clinical diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of Ocular Artifacts in the EEG through Wavelet Transform without using an EOG Reference Channel

This paper presents a statistical method for removing ocular artifacts in the electroencephalogram (EEG) records. Artifacts in EEG signals are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). The removal of ocular artifact from scalp EEGs is of considerable importance for both the automated and visual analysis of underlying brainwave activi...

متن کامل

Removal of Ocular Artifacts from EEG Signals by Fast RLS Algorithm using Wavelet Transform

This paper presents an adaptive filtering method to remove ocular artifacts in the electroencephalogram (EEG) records. The major concern in analyzing EEG signal is the presence of ocular artifacts in EEG records caused due to various factors. It is essential to design specific filters to remove the artifacts in EEG records. Here, we proposed an adaptive filtering method that uses RLS (Recursive...

متن کامل

A Certain Exploration on EEG Signal for the Removal of Artefacts using Power Spectral Density Analysis through Haar wavelet Transform

Electroencephalogram is the method of recording the electrical activity of the brain via sensors (electrodes) placed on the surface of the scalp. EEGs, which are of the order of microvolt, have greater potential for the diagnosis and treatment of mental and brain diseases and abnormalities. However, EEG signals are subject to various kinds of contaminants (i. e) artifacts which arise from human...

متن کامل

Removal of Ocular Artifacts from EEG Signals by Fast RLS Algorithm using Wavelet Transform

This paper presents an adaptive filtering method to remove ocular artifacts in the electroencephalogram (EEG) records. The major concern in analyzing EEG signal is the presence of ocular artifacts in EEG records caused due to various factors. It is essential to design specific filters to remove the artifacts in EEG records. Here, we proposed an adaptive

متن کامل

Certain Analysis on Eeg for the Detection of Eog Artifact Using Symlet Wavelet

This paper presents a statistical method for identification of ocular artifacts in the electroencephalogram (EEG) records. The occurrence of artifacts in EEG signals is due to various factors, like power line interference, EOG (electrooculogram) and ECG (electrocardiogram). The identification of ocular artifact from scalp EEGs is mandatory for both the automated and visual analysis of underlyin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006