Evaluation of the Femoral arteries: Before or After Tumor Treatments using Non-contrast MRA using Subtraction Method based on Velocity Encoding Technique

نویسندگان

  • T. Masui
  • M. Katayama
  • M. Miyoshi
  • K. Sato
  • H. Ikuma
  • H. Seo
  • M. Sugimura
  • M. Ishii
  • N. Takei
  • T. Tsukamoto
چکیده

Introduction; Dynamic contrast MR angiography (C MRA) has been used for the evaluation of the atherosclerotic diseases. For evaluation of patients with renal insufficiency or history with adverse reactions, MR contrast media cannot be used. So far, Non-contrast (NC) MRA with several techniques has been introduced. In the lower extremities, subtraction method between images in diastolic and systolic phases using fast spin echo technique has been used [1]. And in other way, flow preparation pulse (Flow-Prep) based on bipolar velocity encoding to distinguish artery from vein and background has been used with FIESTA and promising results have been obtained [2]. However, inhomogeneous magnetic field especially for lower extremities and slower flow velocity in the artery, FSE based sequence may be utilized. Based on subtraction technique for selective visualization of the artery and vein, Flow Saturation Preparation (Flow-Sat-Prep) technique was utilized [3]. Accordingly, the purpose was to evaluate abilities of NC MRA using Flow-Sat-Prep FSE with subtraction technique for demonstration of superficial femoral arteries compared with C MRA. Theory: In Flow-Sat-Prep method, Non-selective RF pulses sandwich Velocity ENCoding (VENC) and crusher gradients to saturate multi dimensional flows. Flow void occurs along crusher gradient axis because the crusher gradients give different first order moment between stimulated echoes and spin echoes of the flow signals. VENC gradient inverts the flow signals. Reference images are required for image subtraction. To match the contrast of the backgrounds, preparation pulse for the reference images should be simple MLEV-4 without VENC and crusher gradients. Preparation pulse was applied in systolic phase. 3D FSE data acquisition was applied after around 200-300 ms waiting time from Preparation pulse. Arterial and venous signal separation in FSE was obtained with image subtraction between the Flow-Sat-Prep and reference images. STIR was applied to suppress fat signals. Materials and Methods: Population: 20 patients (6 men, 14 women, mean age 55.6 years) were included, who underwent contrast enhanced MR imaging for evaluation of the femoral tumor or femoral arteries. Pathologies were soft part tumor in the thigh in 6, status of post surgical resection of the tumor with artery graft in 6, status of post surgical resection of the tumor with recurrence in 4 or without recurrence in 3, and trauma in one. MR imaging: All images were obtained on a 1.5T MR (HDx or HDe, GE, Milwaukee) with 8 channel phased array multicoils. NC MRA was obtained with two steps: firstly, peripheral arterial gated axial 2D PC cine MR imaging of the femoral artery was obtained and the arterial peak flow velocity and its delay time for triggering on wave were measured. With use of obtained data, peripheral arterial gated Flow-Sat-Prep and reference 3D FSE images were obtained in the coronal plane with TR/TE/ FOV/slice thickness/overlap/matrix; 1600-2400ms/ 51ms/ 35cm/2-3mm/1-1.5mm/256x224-256, 0.5 NEX and reduction factor (RF) 2. Imaging time was 2-4 min to acquire both Flow-Sat-Prep and reference images. C MRA was obtained with 3D gradient echo sequence (EFGRE) using 2.9-3.7ms/0.8-2.8ms/20 deg/35cm/2-3mm/256x160-192 /one NEX/Spec IR/RF2, centric k space ordering. 0.1mmol/kg of gadolinium was injected (0.3ml/sec) and 3D EFGRE was obtained in 24 seconds. Data analysis: Subjective: Image quality, artifacts (blurring), and overlap of the femoral artery and veins were ranked with 5 -point scale (form 1 undiagnostic, bad to 5 excellent, no artifacts). Recognitions of upper, middle and lower portions of the superficial femoral artery were ranked with 5-point scale (1 bad to 5 good). Patency of the arteries with/without stenosis was also evaluated. Two radiologists performed subjective evaluations. Wilcoxon signed rank test was used for comparison between two MRA. All evaluations were made on workstation (Advantage workstation 4.4, GE) and MIP images were generated from each data using MPVR under flexible volume thickness and its orientation changeable by readers. Results: In all 20 patients, NC MRA and C MRA were diagnostic and overall image quality and artifacts were not significantly different between two, respectively (NC:C=4.1:4.3, Fig 1). Recognition of upper-lower portions of the superficial femoral artery was equally made on both MRAs (Fig 2, 3, 4). Selective visualization of the artery was successful in both MRAs (Fig 2, 3, 4). Patency of the grafts after resection of the tumors was confirmed on NC MRA in all the 6 cases (Fig 3). Reference images of NC MRA demonstrated arteries and veins as well as the pathological changes including the tumor and fluids (Fig 4). Summary: NC MRA based on ”Flow-Sat-Prep” FSE subtraction images could demonstrate superficial femoral arteries and graft vessels. NC MRA provided identical information to that of C MRA. Besides no risk of side effects related contrast agents, one of the advantages of NC MRA is feasibility of repeated acquisition of MRA even with different parameters for better quality of images. In conclusion, for the evaluation of the femoral arteries before and after the tumor treatments, anatomical information of the vasculature can be successfully obtained with NC MRA using Flow-Sat-Prep FSE technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا

Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimizatio...

متن کامل

Evaluation of the renal arteries: Comparison of two types of Non-contrast MRA and Dynamic contrast MRA

Introduction; Dynamic contrast MR angiography (C MRA) has made a major role for evaluation of cardiovascular diseases. For evaluation of patients with renal insufficiency or history with adverse reactions, MR contrast media cannot be used. Non-contrast (NC) MRAs with several techniques have been introduced. Currently, we used two types of MRA; FIESTA with flow preparation pulse (Flow-Prep) base...

متن کامل

Non-Contrast Renal MR Angiography: Value of Subtraction of Tagging and Non-Tagging Technique.

PURPOSE The aim of this study was to examine the usefulness of the subtraction technique of non-contrast renal magnetic resonance angiography (MRA) between tagged and non-tagged data collection. MATERIAL AND METHODS We performed renal MRA on eleven healthy volunteers using a 3T MRI unit. For renal MRA, a three dimensional balanced type steady-state free precession (SSFP) sequence (True FISP, ...

متن کامل

Quantification of Blood Flow in Internal Cerebral Artery by Optical Flow Method on Digital Subtraction Angiography in Comparison with Time-Of-Flight Magnetic Resonance Angiography

OBJECTIVE This study compared data on the blood flow velocity in the internal carotid artery, which was obtained using the optical flow method (OFM) with digital subtraction angiography (DSA) and the time-of-flight (TOF) technique using magnetic resonance angiography (MRA). MATERIALS AND METHODS Images were obtained from 12 cerebrovascular patients who underwent both brain DSA and MRA imaging...

متن کامل

Flow Preparation Pulse for Abdominal Non-Contrast-Enhanced MRA

M. Miyoshi, T. Tsukamoto GE Yokogawa Medical Systems, Hino, Tokyo, Japan Abstract Steady State Free Precession (SSFP) yields high blood signal image in short scanning time and it enables Non-Contrast-Enhanced MR Angiography (NCE-MRA) in abdomen. However, SSFP produces bright signal not only in artery but also in vein or stationary fluids. We propose new Flow Preparation (Flow Prep) pulse to dis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008