Revision of the NIST Standard for (223)Ra: New Measurements and Review of 2008 Data.
نویسندگان
چکیده
After discovering a discrepancy in the transfer standard currently being disseminated by the National Institute of Standards and Technology (NIST), we have performed a new primary standardization of the alpha-emitter (223)Ra using Live-timed Anticoincidence Counting (LTAC) and the Triple-to-Double Coincidence Ratio Method (TDCR). Additional confirmatory measurements were made with the CIEMAT-NIST efficiency tracing method (CNET) of liquid scintillation counting, integral γ-ray counting using a NaI(Tl) well counter, and several High Purity Germanium (HPGe) detectors in an attempt to understand the origin of the discrepancy and to provide a correction. The results indicate that a -9.5 % difference exists between activity values obtained using the former transfer standard relative to the new primary standardization. During one of the experiments, a 2 % difference in activity was observed between dilutions of the (223)Ra master solution prepared using the composition used in the original standardization and those prepared using 1 mol·L(-1) HCl. This effect appeared to be dependent on the number of dilutions or the total dilution factor to the master solution, but the magnitude was not reproducible. A new calibration factor ("K-value") has been determined for the NIST Secondary Standard Ionization Chamber (IC "A"), thereby correcting the discrepancy between the primary and secondary standards.
منابع مشابه
Utility of F-18 FDG PET/CT for Detection of Bone Marrow Metastases in Prostate Cancer Patients Treated with Radium-223
A 76-year-old man with symptomatic bone metastases from castrationresistant prostate cancer underwent Radium-223-dichloride (Ra-223) therapy. Before Ra-223 therapy, he had normal peripheral blood cell counts. Ra-223 therapy relieved his shoulder and low back pain. The elevation of the serum prostate-specific antigen (PSA), doubling every month during Ra-223 therapy, suggested a PSA flare or rel...
متن کاملExpression and Purification of the luciferase enzyme and in Vivo ATP Assay
Introduction: Gene expression and purification of luciferases from the firefly, Lampyris turkestanicus, and optimization of cellular ATP measurements were performed. Methods: cDNA encoding luciferases from Lampyris turkestanicus was transferred from pQE30 vector into pET28a expression vector and pLtu28 was built. Newly constructed vector was expressed in E. coli XL1 Blue and the recombinant l...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملEvaluation of Leukoreduction in Packed Cell Units Filtered by Home-Made Bedside Filters: Pre and Post Revision of Product Technology and Materials According to Standard Values
Introduction: Leukocytes causing a wide variety of side effects after transfusion are present in all blood products prepared by standard methods. As a consequence, the use of filter technology for leukoreduction has been widely practiced .According to AABB accreditation in 1996, leukoreduced blood components must contain less than 5×106 leukocytes per unit, but sometimes this value is higher ev...
متن کاملAPPLICATION OF NIST ^Rn EMANATION STANDARDS FOR CALIBRATING ^Rn MONITORS
Several years of research in developing a radon emanation standard by the National Institute of Standards and Technology (NIST) has led to NIST Radon Emanation Standard SRM 4968 (Journal of Research of the MST 100:629-639; 1996). This new standard is based on a polyethylene -encapsulated ""Ra solution that has been demonstrated to emanate a well-characterized and known quantity "̂Rn when employe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of research of the National Institute of Standards and Technology
دوره 120 شماره
صفحات -
تاریخ انتشار 2015