Disequilibrium calorimetry for determination of ultrasonic power in sonochemistry

نویسندگان

  • Mario Plattes
  • Christian Köhler
  • Tom Gallé
چکیده

The two most characteristic properties of an ultrasonic wave are the frequency and the power. It is therefore important to determine the power in a given reactor. This can be done by calorimetry, i.e. by measuring the temperature rise in the vessel during sonication starting at thermal equilibrium with the surroundings (classic calorimetry) [1-3]. However, the classic ultrasonic calorimetry has drawbacks. In particular it is difficult to evaluate the temperature rise at thermal equilibrium, because the relevant initial time and temperature intervals are small and measurement errors in the temperature readings are large. Also the initial temperature response of the probe is complex [4]. The authors propose to start the calorimetric measurement at thermal disequilibrium, i.e. with a lower temperature in the reaction vessel. During sonication the temperature in the reaction vessel rises faster than in the surrounding and passes thermal equilibrium. The acoustic power transferred to the vessel at thermal equilibrium can then be calculated. The method consists of: •Setting up the reaction vessel at lower temperature than the surroundings (ultrasonic bath or air).•Measuring temperature rise in the reaction vessel and the surroundings during sonication.•Determine the temperature rise at intercept by interpolation and calculate the ultrasonic power in the reaction vessel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of a 20 kHz sonoreactor. Part I: analysis of mechanical effects by classical and numerical methods.

Numerical simulations have been carried out in order to characterize the ultrasonic field propagation and to obtain the spatial distribution of the mechanical effect derived from it. The results have been compared with those obtained with different classical physical methods (calorimetry, aluminium foil erosion, thermal probes) and have given useful information about the influence of the presen...

متن کامل

Comparison of hydroxyl radical formation in aqueous solutions at different ultrasound frequencies and powers using the salicylic acid dosimeter.

Ultrasonic frequencies of 20kHz, 382kHz, 584kHz, 862kHz (and 998kHz) have been compared with regard to energy output and hydroxyl radical formation utilising the salicylic acid dosimeter. The 862kHz frequency inputs 6 times the number of Watts into water, as measured by calorimetry, with the other frequencies having roughly the same value under very similar conditions. A plausible explanation i...

متن کامل

A study to determine whether cavitation occurs around dental ultrasonic scaling instruments.

The aim of this investigation was to determine if cavitation occurred around dental ultrasonic scalers and to estimate the amount of cavitation occurring. Three styles of tip (3 x TFI-10, 3 x TFI-3, 3 x TFI-1) were used, in conjunction with a Cavitron SPS ultrasonic generator (Dentsply, USA), to insonate terephthalic acid solution. The hydroxyl radical, [*OH], concentration, produced due to cav...

متن کامل

Effects of ultrasonic treatments on the polyphenol and antioxidant content of spinach extracts.

The objective was to test ultrasound treatments on spinach leaves during extraction, and conventional extraction was used as a control. The effects of different combinations of the ultrasonic water bath factors tested on phenolic compound yields included frequency (37 and 80 kHz), exposure time (5, 10, 15, 20, 25, and 30 min), temperature (30, 40, and 50°C), and ultrasonic power (30%, 50%, and ...

متن کامل

Characterisation of mixing rate due to high power ultrasound.

For meaningful assessment of results from laboratory and pilot plant trials, it is often necessary to know the mixing characteristics within the ultrasonic reactors. Previous workers have used conductivity measurements in an attempt to characterize the residence time distribution in ultrasonic reactors, but these results do not provide direct data on the mixing within the high power region adja...