Predicting visual performance from optical quality metrics in keratoconus.

نویسندگان

  • Paul Schoneveld
  • Konrad Pesudovs
  • Douglas J Coster
چکیده

PURPOSE The aim was to identify optical quality metrics predictive of visual performance in eyes with keratoconus and penetrating keratoplasty (PK) for keratoconus. METHODS Fifty-four participants were recruited for this prospective, cross-sectional study. Data were collected from one eye of each participant: 26 keratoconus, 10 PK and 18 normal eyes: average age (mean +/- standard deviation) 45.2 +/- 10.6 years and 56 per cent female. Visual performance was tested by 10 methods including visual acuity (VA), both high and low contrast (HC- and LC-) and high and low luminance (LL-), and Pelli-Robson contrast sensitivity, all tested with and without glare. Corneal first surface wavefront aberrations were calculated from Orbscan corneal topographic data using VOLPro software v7.08 (Sarver and Associates) as a tenth-order Zernike expansion across three, 4.0 mm and 5.0 mm pupils and converted into 31 optical quality metrics. Pearson correlation coefficients and linear regression were used to relate wavefront aberration metrics to visual performance. RESULTS Visual performance was highly predictable from optical quality with the average correlation of the order of 0.5. Pupil fraction metrics (for example, PFWc) were responsible for all of the highest correlations at large pupils for example, with HCVA (r = 0.80), LCVA (r = 0.80) and LLLCVA (r = 0.75). Image plane metrics, derived from the optical transfer function (OTF) were responsible for most of the highest correlations at smaller pupils for example, volume under the OTF (VOTF) with HCVA (r = 0.76) and LCVA (r = 0.73). CONCLUSIONS As in normal eyes, visual performance in keratoconus was predicable from optical quality; albeit by different metrics. Optical quality metrics predictive of visual performance in normal eyes, for example, visual Strehl, lack the dynamic range to represent visual performance in highly aberrated eyes with keratoconus. Optical quality outcomes for keratoconus could be reported using many different metrics, but pupil fraction metrics, for example PFWc, perform best for highly aberrated eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Effectiveness of Daylight Performance Metrics in Predicting Visual Comfort Case Study: Educational Architecture Design Studios in Tehran

It is essential to ensure that adequate daylight penetrates in, especially, educational environments. In spite of positive significant impacts of daylight on the emotions, concentration, and learning of students, an exceeded amount of light will lead to glare and visual dissatisfaction. Over the last few years, with the help of simulation tools and lighting indices, it is possible to predict li...

متن کامل

Visual Performance and Optical Quality of Standardized Asymmetric Soft Contact Lenses in Patients With Keratoconus.

Purpose To evaluate the visual performance and optical quality of a standardized asymmetric soft contact lens (SCL) used for correction of higher-order aberrations (HOAs) in eyes with keratoconus. Methods We included 30 eyes (26 patients) with keratoconus (average K: 45.7 ± 2.3 diopters [D]). The patients were subjected to corneal tomography, aberrometry, measurements of manifest refraction a...

متن کامل

Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery

PURPOSE To prospectively evaluate intracorneal ring segment (ICRS) implantation on quality of life (QoL) of patients with keratoconus changes and identify factors responsible. METHODS Sixty-nine eyes of 42 keratoconus patients were implanted with the Keraring (Mediphacos, Belo Horizonte, Brazil). Best corrected visual acuity (BCVA), refraction, and steep keratometry were analyzed 3 months and...

متن کامل

The Lower- and Higher-Order Aberrations of the Eye

Keratoconus causes a reduction in the optical quality of the eye as a result of corneal distortion, corneal scarring and higher-order aberrations. The correction of these optical aberrations would significantly improve the visual performance of keratoconic eyes. However the first step would be to measure the optical flaws in keratoconus accurately, which in itself presents a challenge. This pap...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical & experimental optometry

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2009