Optimization of "wired" enzyme O2-electroreduction catalyst compositions by scanning electrochemical microscopy.

نویسندگان

  • José L Fernández
  • Nicolas Mano
  • Adam Heller
  • Allen J Bard
چکیده

“Wired” enzyme electrodes, comprising enzymes connected electrically through redox polymers, which swell to give electron-conducting hydrogels, are already used in experimental subcutaneously implanted electrodes for the continuous monitoring of glucose in diabetics and may be used in future miniature, microwatt producing, membrane-less biofuel cells. The subcutaneously implanted electrodes comprise, in addition to the “wired” enzyme film that transduces the glucose flux to a current, a glucose flux-controlling membrane, which defines the measurable glucose concentration range, and optionally, a bioinert film. The membrane-less miniature biofuel cells comprise a “wired” glucose oxidase anode, and a “wired” bilirubin oxidase or laccase cathode. Optimizing the performance of these devices requires synthesis and characterization of new redox polymers, 5] defining the optimal enzyme–cross-linker–redoxpolymer compositions, and synthesis and optimization of flux controlling and bioinert membranes. A key parameter, which is usually explored first, is the polymer/enzyme ratio. An excessive enzyme weight fraction can decrease the current density, because the enzyme, unlike the redox polymer, is an electronic insulator. Furthermore, if the enzyme weight fraction is high enough for the net negative charge of glucose oxidase to balance the positive charge of the redox polymer, an electrostatic adduct that shows poor electronic conductivity precipitates. Moreover, when the weight fraction of the redox polymer is excessive, the flux of electrons is reduced, because of the smaller number of enzyme molecules. The effort and material expended in the optimization process 11] can be reduced by combinatorial screening techniques exemplified by optimization through scanning electrochemical microscopy (SECM), a technique that has been extensively used for evaluating the activity of enzymatic systems and whose utility is demonstrated herein. Because only optimization of an exemplary parameter, the weight fraction of the multicopper oxidase bilirubin oxidase (BOD) or laccase, of a biofuel cell cathode was performed, the study does not provide as yet a fully optimized electrode, for which additional parameters, including the total loading and the weight% of the cross-linker, would have to be defined, along with the thickness of the electrode. The results obtained establish, nevertheless, that SECM screening of compositionally varying arrays of mm-size spot electrodes yields results identical with those obtained with discreet rotating disk electrodes, but much more efficiently in terms of speed and material required. Ternary mixtures of enzyme, cross-linker, and redox polymer, with compositions ranging from pure enzyme to pure polymer, were prepared from aqueous solutions of BOD from Trachyderma tsunodae (8 mgmL 1 in pH 7.2 20-mm phosphate buffer) or laccase from Coriolus hirsutus (8.6 mgmL 1 in pH 5.0 20-mm citrate buffer), and PAAPVI-[Os(4,4’-dichloro-2,2’-bipyridine)2Cl] 1+/2+ (8 mgmL ) or PAA-PVI-[Os(tpy)(dme-bpy)Cl] (8.6 mgmL ), respectively (PAA= poly(1-carboxy-1,2-ethanediyl, PVI= poly(1imidazolyl-1,2-ethanediyl, tpy= 2,2’:6’,2’’-terpyridine, dmebpy= 4,4’-dimethyl-2’,2-bipyridine). A solution of polyethylene glycol diglycidyl ether at 2 mgmL 1 (PEDGE, Polysciences Inc.) was used as the cross-linker. Arrays of spots containing these mixtures were deposited on glassy carbon (GC) plates 15 B 15B 1mm (Alfa) by using a piezo-based micro-arrayer, a device similar to that used by Schuhmann and co-workers for micro-patterning of enzymatic biosensors. A commercial piezo-dispenser MicroJet AB-01-60 (MicroFab) with an outlet aperture of 60 mm, that dispenses on-demand picoliter-sized ( 100 pL) droplets by application of potential pulses (50 V, 25 ms), was installed onto the head of a digital plotter (Houston Instruments DMP-5) to control its position with a resolution of 100 mm/step. Figure 1 shows the preparation scheme. The dispenser was filled with polymer solution (3 mL), which was dispensed in a programmed number of drops at each site. To test for reproducibility, each composition was prepared in duplicate or triplicate. Thus, the arrays contained 11 rows and two columns of spots. Typically, the first two-spot row contained 10 drops per spot (pure polymer), the next row 9 drops per spot and so on down to and the tenth row with 1 drop per spot. The dispenser was [*] Dr. J. L. Fern ndez, Prof. Dr. A. J. Bard Chemistry and Biochemistry University of Texas at Austin Austin, TX 78712 (USA) Fax: (+1)512-471-0088 E-mail: [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oxygen is electroreduced to water on a "wired" enzyme electrode at a lesser overpotential than on platinum.

The first enzyme-based catalyst that is superior to platinum in the four-electron electroreduction of oxygen to water is reported. The smooth Pt cathode reached half and 90% of the mass transport-limited current density at respective overpotentials of -0.4 and -0.58 V in 0.5 M sulfuric acid, and only at even higher overpotentials in pH 7.2 phosphate buffer. In contrast, the smooth "wired" bilir...

متن کامل

Combinatorial biomimetics. optimization of a composition of copper(II) poly-L-histidine complex as an electrocatalyst for O2 reduction by scanning electrochemical microscopy.

A simple approach to prepare and characterize biomaterial-based electrocatalysts for oxygen reduction was carried out. Poly-l-histidine was used as a matrix and ligand to complex Cu2+ to mimic the active sites of laccases. A modified glassy carbon (GC) electrode with Cu2+-poly-l-histidine complex decreases the oxygen reduction overpotential as compared with the bare GC electrode. An array of Cu...

متن کامل

Thermodynamic guidelines for the design of bimetallic catalysts for oxygen electroreduction and rapid screening by scanning electrochemical microscopy. M-co (M: Pd, Ag, Au).

We propose guidelines for the design of improved bimetallic (and related) electrocatalysts for the oxygen reduction reaction (ORR) in acidic media. This guide is based on simple thermodynamic principles assuming a simple mechanism where one metal breaks the oxygen-oxygen bond of molecular O(2) and the other metal acts to reduce the resulting adsorbed atomic oxygen. Analysis of the Gibbs free en...

متن کامل

Non-modified and platinum/polyaniline-modified carbon fiber fabric electrodes: preparation and electrochemical behavior towards amaranth electroreduction/electrooxidation electrolysis

The electrochemical behavior of non-modified, Pt-modified and Pt/polyanilinemodified carbon fiber textile electrodes was studied through a series of electroreduction/electrooxidation electrolyses, performed under potentiostatic conditions, for an amaranth/sulphuric solution in the presence or absence of chloride ion. Both Pt electrodeposition and aniline polymerization were carried out potentio...

متن کامل

Rapid Characterization of Oxygen-Evolving Electrocatalyst Spot Arrays by the Substrate Generation/Tip Collection Mode of Scanning Electrochemical Microscopy with Decreased O2 Diffusion Layer Overlap

A simple approach for the screening of oxygen evolution reaction (OER) electrocatalyst arrays by scanning electrochemical microscopy (SECM) in the substrate generation/tip collection (SG/TC) mode is described. The methodology is based on the application of a series (9−10 replicates) of double-potential steps to a catalytically active substrate electrode, which is switched between potentials whe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Angewandte Chemie

دوره 43 46  شماره 

صفحات  -

تاریخ انتشار 2004