The accuracy of dry gas meters at continuous and sinusoidal flows.
نویسندگان
چکیده
Dry gas meters are used in physiology laboratories to measure minute ventilation. The accuracy of these meters must be known since an error, of for instance 5%, affects the subsequent calculations for oxygen consumption by the same amount. Two precalibrated DTM-325 dry gas meters (American Meter Co., Philadelphia, PA, USA) were therefore tested for accuracy against a 350 l Collins chain-compensated gasometer. Provided that at least 25 l was passed per measurement then: a. continuous flows (air saturated with water vapour) between 60 and 150 l.min-1 were measured with an error of < 1%; and b. sinusoidal flows (ambient air) between 8 and 100 l.min-1 were misread by < 1% and the error was still within 2% at 140 l.min-1. It may, therefore, be concluded that the two precalibrated dry gas meters studied are valid volume measuring devices.
منابع مشابه
The Performance of a Multi-path Ultrasonic Meter with Wet Gas
Due to increasing economic pressures in natural gas production, there is a recognized demand for flow meters that are able to measure when a significant quantity of liquid is present in gas flows. The key issues are that the liquid quantity is often unknown and its presence can affect the operation of traditional dry gas meters making the gas flow readings inaccurate. A number of techniques are...
متن کاملNumerical Analysis of the Effect of Sinusoidal Pressure Path on Thinning of Tube in Hot Metal Free Bulging Process
Light-weight and high strength alloys such as Al-Mg alloys are used in order to reduce the weight of industrial components. However these materials should be formed at elevated temperatures due to their poor formability at room temperature. Hot metal gas forming is one of the high-tech forming processes that is used to solve this problem. Recent investigation on tube hydroforming showed positiv...
متن کاملNumerical Analysis of the Effect of Sinusoidal Pressure Path on Thinning of Tube in Hot Metal Free Bulging Process
Light-weight and high strength alloys such as Al-Mg alloys are used in order to reduce the weight of industrial components. However these materials should be formed at elevated temperatures due to their poor formability at room temperature. Hot metal gas forming is one of the high-tech forming processes that is used to solve this problem. Recent investigation on tube hydroforming showed positiv...
متن کاملEffects of coupling on turbulent gas-particle boundary layer flows at borderline volume fractions using kinetic theory
This study is concerned with the prediction of particles’ velocity in a dilute turbulent gas-solidboundary layer flow using a fully Eulerian two-fluid model. The closures required for equationsdescribing the particulate phase are derived from the kinetic theory of granular flows. Gas phaseturbulence is modeled by one-equation model and solid phase turbulence by MLH theory. Resultsof one-way and...
متن کاملPrecision and accuracy of Morgan ventilometers at continuous and sinusoidal flows.
The P.K. Morgan Mark II Ventilometer comprises a turbine transducer and a control/readout unit, which contains either a VENTX5A or VENTX6A programme. This equipment is used to measure minute ventilation during oxygen consumption tests. The precision and accuracy of six of these devices (a VENTX5A with two turbines, and two VENTX6As each with two different turbines) were examined during continuo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 5 9 شماره
صفحات -
تاریخ انتشار 1992