A simple, accurate and universal method for quantification of PCR.
نویسندگان
چکیده
BACKGROUND Research into gene expression enables scientists to decipher the complex regulatory networks that control fundamental biological processes. Quantitative real-time PCR (qPCR) is a powerful and ubiquitous method for interrogation of gene expression. Accurate quantification is essential for correct interpretation of qPCR data. However, conventional relative and absolute quantification methodologies often give erroneous results or are laborious to perform. To overcome these failings, we developed an accurate, simple to use, universal calibrator, AccuCal. RESULTS Herein, we show that AccuCal quantification can be used with either dye- or probe-based detection methods and is accurate over a dynamic range of ≥10(5) copies, for amplicons up to 500 base pairs (bp). By providing absolute quantification of all genes of interest, AccuCal exposes, and circumvents, the well-known biases of qPCR, thus allowing objective experimental conclusions to be drawn. CONCLUSION We propose that AccuCal supersedes the traditional quantification methods of PCR.
منابع مشابه
A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملDevelopment of qRT-PCR Test for Quantification of Rubella Virus in Commercially Available Vaccines
vaccines is considered as a critical point and in-process of quality control (IPQC) test of vaccine production. Rapid tests, like real time PCR, are more appropriated when the production occurs at industrial scale because of the amounts of starting materials and the excess of consumed time required. In the current study, a real-time quantitative reverse transcription-polymerase chain reaction...
متن کاملتعیین کمی بار ویروسی هپاتیت C با استفاده از روش Real-Time PCR In-House در بیماران آلوده به هپاتیت C در شهرستان خرم آباد
Background : Molecular diagnostic methods are among major tools in management of hepatitis C virus (HCV) in infected patients. Many studies have shown that viral load is associated with stage of infection and response to treatment. Therefore, the evaluation and quantification of viral load is very important. The goal of this study is implementation of inexpensive, yet accurate method for quanti...
متن کاملQuantification of Linagliptin by Chemical Derivatization with Appliance of Chromogenic Reagents
Two simple, specific, accurate, precise, sensitive and cost effectivespectrophotometric methods have been developed and validated for quantification oflinagliptin in pure form and pharmaceutical formulations. Method A is established onthe computation of absorbance of purple coloured chromogen complex at 463 nmwhich is formed by the condensation reaction of the primary amine group oflinagliptin ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC biotechnology
دوره 16 شماره
صفحات -
تاریخ انتشار 2016