Radiation Quantities and Units

ثبت نشده
چکیده

The unique radiation exposure conditions that exist in computed tomography (CT), during which thin slices of the patient are irradiated by a narrow, fan-shaped beam of x rays emitted from the x-ray tube during its rotation around the patient, have required the use of special dosimetry techniques to characterize the radiation doses to patients and to monitor CT system performance. This section describes the basic dosimetry quantities used to indicate patient doses during CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of radionuclide transfer in terrestrial and freshwater environments.

The paper gives an overveiew of radioecological concepts, reference information on plants and soils used in the project. Main classification schemes applied to summarize the data on radionuclide transfer to plants are also described. Generic quantities and units used in the current document are also given. They are mainly defined according to the the ICRU 65 report. 1. DEFINITIONS, QUANTITIES A...

متن کامل

Radiation Units, Limits and Dose Constraints

Y. Lemoigne and A. Caner (eds.), Radiation Protection in Medical Physics, NATO Science for Peace and Security Series B: Physics and Biophysics 1, DOI 10.1007/978-94-007-0247-9_2, © Springer Science+Business Media B.V. 2011 Abstract A number of radiation units exist for representing radiation dose to patients, staff, public and quantities for radiation equipment performance in radiological pract...

متن کامل

Dosimetric Concepts and Calibration of Instruments

The development of dosimetric concepts and the definition of specific quantities for use in radiation protection has a long history. An important basis for the present concepts was already provided in the 60’s and 70’s by both the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU). In 1991 in its Publication 60 ...

متن کامل

Methods for monitoring patient dose in dental radiology.

Different types of X-ray equipment are used in dental radiology, such as intra-oral, panoramic, cephalometric, cone-beam computed tomography (CBCT) and multi-slice computed tomography (MSCT) units. Digital receptors have replaced film and screen-film systems and other technical developments have been made. The radiation doses arising from different types of examination are sparsely documented a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005