Cerebral blood flow during cardiopulmonary bypass in man: effect of arterial filtration.

نویسندگان

  • L Henriksen
  • E Hjelms
چکیده

Cerebral blood flow was recorded in 39 patients undergoing cardiac surgery by intraarterial injection of xenon 133. There were three subgroups of patients: 10 patients had a 20 micron arterial filter (Johnson) and 11 a 40 micron filter (Pall), and 18 had no arterial filtration. All patients had a 40 micron (Pall) filter in the coronary suction line. Significant changes in cerebral blood flow occurred during extracorporeal circulation (p less than 0.0001). For all patients cerebral blood flow increased from a resting prebypass level of 30 to 46 and 57 ml/100 g a minute during initial and stable hypothermic extracorporeal circulation respectively. Both measurements were obtained at 26 degrees C and the recordings were made on average 12 and 55 minutes after the extracorporeal circulation was started. During rewarming cerebral blood flow increased to 64, 53, 41, and 36 ml/g a minute at 31 degrees, 33 degrees, 35 degrees, and 37 degrees C respectively, and when measured four and 16 minutes on average after bypass it was 44 and 41 ml/100 g a minute. This general brain hyperperfusion was noticed in all patients with a high enough mean blood pressure to produce hyperaemia. Interposing 20 and 40 micron arterial filters reduced cerebral blood flow but did not prevent this hyperaemia. The cerebral autoregulation, which maintains a constant cerebral blood flow within wide limits of perfusion pressures, was not affected by arterial filtration. The lower limit of blood pressure at which a further reduction in blood pressure was followed by a reduction in cerebral blood flow was around 60 mm Hg in all three groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The relation between arterial oxygen tension and cerebral blood flow during cardiopulmonary bypass.

OBJECTIVES Neurological impairment occurs in up to 25% of infants undergoing cardiopulmonary bypass with or without circulatory arrest. Potential causes include alterations in cerebral blood flow, hypoxia and embolisation. During cardiopulmonary bypass, arterial oxygen tension is maintained at levels which under normal conditions cause cerebral vasoconstriction; this is a potential mechanism fo...

متن کامل

Monitoring cerebral blood flow pressure autoregulation in pediatric patients during cardiac surgery.

BACKGROUND AND PURPOSE The limits of cerebral blood flow-pressure autoregulation have not been adequately defined for pediatric patients. Mean arterial blood pressure below these limits might contribute to brain injury during cardiac surgery. The purpose of this pilot study was to assess a novel method of determining the lower limits of pressure autoregulation in pediatric patients supported wi...

متن کامل

Renal hemodynamics, function, and oxygenation during cardiac surgery performed on cardiopulmonary bypass: a modeling study

Acute kidney injury, a prevalent complication of cardiac surgery performed on cardiopulmonary bypass (CPB), is thought to be driven partly by hypoxic damage in the renal medulla. To determine the causes of medullary hypoxia during CPB, we modeled its impact on renal hemodynamics and function, and thus oxygen delivery and consumption in the renal medulla. The model incorporates autoregulation of...

متن کامل

The Effect of Zero Balance Ultrafiltration of Priming Blood on Clinical Outcomes of Infants Undergo Cardiopulmonary Bypass

Introduction: Pediatric Cardiopulmonary Bypass (CPB) circuit invariably requires priming with Packed Red Blood Cells (PRBCs). Metabolic composition of stored PRBCs is unphysiological. Commencement of PRBC primed CPB leads to rapid transfusion of massive metabolic load. This predisposes pediatric patients to the risk of complications such as electrolyte disturbances, citrate toxicity, acidosis a...

متن کامل

مقایسه دی اکسیدکربن انتهای بازدمی و شریانی در بیماران کاندید پیوند عروق کرونر

Background: Measuring end tidal carbon dioxide (ETCo2) is one of the methods used for estimating arterial carbon dioxide (PaCo2) during general anesthesia. ETCo2 measurements maybe obviate the need for repeating arterial puncture for determination of arterial PaCo2. This study performed to determine the accuracy of ETCo2 levels as a measure of PaCo2 levels in patients undergoing coronary artery...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 41 5  شماره 

صفحات  -

تاریخ انتشار 1986