Assessment of Prosthesis Alignment after Revision Total Knee Arthroplasty Using EOS 2D and 3D Imaging: A Reliability Study
نویسندگان
چکیده
INTRODUCTION A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA). METHODS Forty anteroposterior and lateral images of 37 rTKA patients were included. Two observers independently performed measurements on these images twice. Varus/valgus angles were measured in 2D (VV2D) and 3D (VV3D). Intraclass correlation coefficients and the Bland and Altman method were used to determine reliability. T-tests were used to test potential differences. RESULTS Intraobserver and interobserver reliability were excellent for VV2D and VV3D. No significant difference or bias between the first and second measurements or the two observers was found. A significant mean and absolute difference of respectively 1.00° and 1.61° existed between 2D and 3D measurements. CONCLUSIONS EOS provides reliable varus/valgus measurements in 2D and 3D for the alignment of the knee joint with a knee prosthesis. However, significant differences exist between varus/valgus measurements in 2D and 3D.
منابع مشابه
The Validity of a New Low-Dose Stereoradiography System to Perform 2D and 3D Knee Prosthetic Alignment Measurements
INTRODUCTION The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D. METHODS EOS images were made of a lower limb phantom contain...
متن کاملOutcome of revision in comparison with primary total knee arthroplasty in Iran
Abstract Background: In the recent decade, many primary total knee arthroplasties have been carried out in Iran and the number of revision cases is expected to rise with the aging population. The aim of this study was to report the outcome of revision surgery in the country and make a comparison between the outcome of revision and that of the primary arthroplasty. Methods: Retrospectivel...
متن کاملDetermination of the Mechanical Axis of the Femur Using 3d-2d Model to X-ray Registration
For a successful total knee arthroplasty (TKA) and long prosthesis lifespan, correct alignment of the implant components as well as proper soft tissue balancing are of major importance. Studies show that an alignment within +/-3° varus/valgus is correlated with a better outcome (Baethis2004). While conventional planning methods only rely on 2D X-ray images, computer assisted techniques incorpor...
متن کاملRevision Total Knee Arthroplasty Using the Modern Constrained Condylar Knee Prosthesis
OBJECTIVE To determine whether the second-generation constrained condylar prosthesis provided satisfactory results in revision total knee arthroplasty. METHODS A series of 41 cases of revision total knee arthroplasty using the second-generation constrained condylar knee prosthesis was reviewed. The series comprised 7 men and 34 women with a mean age of 73.2 years. The original diagnosis was p...
متن کاملKnee Fusion or Above-The-Knee Amputation after Failed Two-Stage Reimplantation Total Knee Arthroplasty
Prosthetic joint infection (PJI) is a serious complication of total knee arthroplasty (TKA). Control of infection after a failed two-stage TKA is not always possible, and the resolution of infection may require an above-knee amputation (AKA) or a the-knee (KF). The purpose of this review is to determine which treatment method (AKA or KF) yields better function and ambulatory status for patients...
متن کامل