Minimization of Nyquist ghosting for echo-planar imaging at ultra-high fields based on a "negative readout gradient" strategy.
نویسندگان
چکیده
PURPOSE To improve the traditional Nyquist ghost correction approach in echo planar imaging (EPI) at high fields, via schemes based on the reversal of the EPI readout gradient polarity for every other volume throughout a functional magnetic resonance imaging (fMRI) acquisition train. MATERIALS AND METHODS An EPI sequence in which the readout gradient was inverted every other volume was implemented on two ultrahigh-field systems. Phantom images and fMRI data were acquired to evaluate ghost intensities and the presence of false-positive blood oxygenation level-dependent (BOLD) signal with and without ghost correction. Three different algorithms for ghost correction of alternating readout EPI were compared. RESULTS Irrespective of the chosen processing approach, ghosting was significantly reduced (up to 70% lower intensity) in both rat brain images acquired on a 9.4T animal scanner and human brain images acquired at 7T, resulting in a reduction of sources of false-positive activation in fMRI data. CONCLUSION It is concluded that at high B(0) fields, substantial gains in Nyquist ghost correction of echo planar time series are possible by alternating the readout gradient every other volume.
منابع مشابه
Optimized acquisition strategy for reference-free reduction of Nyquist ghosting in EPI at 7 T
Introduction fMRI commonly employs the echo planar imaging (EPI) sequence because of its favourable sensitivity, and its very high sampling efficiency which allows ‘single-shot’ imaging of a brain slice within typically ~70 ms. This is achieved by traversing k-space under an oscillating readout gradient, and so every other k-space line needs to be time-reversed (‘flipped’) before Fourier recons...
متن کاملImproving EPI Imaging Quality and Sound Levels with Bandwidth Selection
K. McMahon, A. Pringle, M. Eastburn, D. Maillet Centre for Magnetic Resonance, University of Queensland, Brisbane, Queensland, Australia Introduction: Echo planar imaging (EPI) is a rapid sequence that has been applied with great success to diffusion, perfusion and functional magnetic resonance imaging (fMRI) of the brain. However, the oscillating gradients in EPI can produce artefacts such as ...
متن کاملRobust EPI Nyquist ghost elimination via spatial and temporal encoding.
Nyquist ghosts are an inherent artifact in echo planar imaging acquisitions. An approach to robustly eliminate Nyquist ghosts is presented that integrates two previous Nyquist ghost correction techniques: temporal domain encoding (phase labeling for additional coordinate encoding: PLACE and spatial domain encoding (phased array ghost elimination: PAGE). Temporal encoding modulates the echo plan...
متن کاملCorrection of EPI Nyquist ghosting caused by the non-uniform frequency response of the MRI receiver chain
O. Josephs, N. Weiskopf, R. Deichmann Wellcome Department of Imaging Neuroscience, University College London, London, United Kingdom Introduction For the majority of rectilinear echo-planar imaging (EPI) sequences, every other phase-encoding (PE) line is acquired with an inverted readout (RO) gradient. Any effect that leads to a signal dependence on the RO direction and thus to a systematic dif...
متن کاملIterative Tuning of System Delay and Phase Correction for Echo-Planar Imaging
Introduction Echo-planar imaging (EPI) suffers from ghosting artifacts if the sample positions in k-space are not accurately known. Many effects lead to a distortion of the ideal gradient waveforms and cause differences in the sample positions for echoes acquired with positive and negative readout gradient polarity. Various methods have been developed to compensate for them, which rely on eithe...