Finite element analysis of locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation
نویسندگان
چکیده
Objective The optimal plate for fixation of tarsometatarsal joint injuries is controversial. The objective of this study was to compare the biomechanical characteristics between a locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation. Method Finite element analysis was used after establishment of a first tarsometatarsal joint fracture-dislocation model. Two implant simulations using a locking plate and five-hole 1/4 tubular plate were designed to simulate fixation of the fracture-dislocation. The displacement of the first tarsometatarsal articular surface and the stress distribution in the implants were calculated. Results A 700-N load was applied to both models. The minimum displacement of the articular surface in the locking plate and 1/4 tubular plate model was 0.6471 mm and 0.3833 mm, respectively. The maximum principal stress in the locking plate and 1/4 tubular plate was 1.212 × 103 MPa and 1.107 × 103 MPa, respectively. Conclusion Use of a 1/4 tubular plate is recommended for fixation of first tarsometatarsal joint fracture-dislocation after consideration of other factors such as economical issues.
منابع مشابه
The biomechanical study of the influence to the forefoot plantar pressure of the first tarsometatarsal joint fracture-dislocation fixed by three different implants
OBJECTIVES To study the influence of forefoot plantar pressure of the first tarsometatarsal joint fracture-dislocation by three different implants to provide experimental reference in selecting implants. METHODS Eight fresh foot specimens were made into the models of the first tarsometatarsal joint fracture-dislocation, which were fixed with 3.5 mm cortical screw, 1/4 tubular plate and compre...
متن کاملInfluence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
BACKGROUND For internal fixation of AO classification Type B lateral malleolar fracture, insertion of lag screws into the fracture plane and fixation with a one-third tubular plate as a neutralization plate are the standard treatment procedures. The one-third tubular plate is processed to a hook shape and hung on the distal end of the fibula. In this study, to compare the function of the hook a...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملSimultaneous of Mid Third Clavicle Fracture and Type 3 Acromioclavicular Joint Dislocation; A Case Report
Simultaneous mid third clavicle fracture and acromioclavicular joint dislocation is a rare combination injury, as a result of high-energy trauma. We report a patient with a middle third clavicle fracture and ipsilateral grade three-acromioclavicular joint dislocation, which is a rare combination. The patient wanted to get back to work as soon as possible, so the fracture was fixed with recons...
متن کامل