Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient

نویسندگان

  • Massimo Bertolissi
  • Flavio Bassi
  • Adriana Di Silvestre
  • Francesco Giordano
چکیده

BACKGROUND: We evaluated the effect on the respiratory gas exchange of the 30 degrees head-down position and the complete covering of the face by sterile drapes. These are used to cannulate the internal jugular vein and position the pulmonary artery catheter in the cardiosurgical patient. During the two manoeuvres, 20 coronary patients and 10 patients with end-stage heart disease were supplied with oxygen (FiO2 =0.4) by a Venturi mask, while 20 coronary patients breathed room air. The arterial blood samples to measure oxygen (PaO2) and carbon dioxide (PaCO2) tension and oxygen saturation (SaO2) were analysed by a blood gas system. RESULTS: The contemporary application of the head-down position and the drapes over the face significantly increased PaO2 and SaO2 in all the patientssupplied with oxygen. Without the head-down position, leaving the drapes over the face, did not significantly change the two parameters in the coronary patients supplied with oxygen, but induced a significant increase in PaO2 and SaO2 in the patients with end-stage heart disease. In the coronary patients that were breathing room air, PaO2 and SaO2 were stable throughout the study. CONCLUSIONS: We conclude that the 30 degrees head-down position and the complete covering of the face by drapes does not interfere with respiratory gas exchange and can be safely performed in coronary patients supplied with oxygen or breathing room air and in patients with end-stage heart disease supplied with oxygen (FiO2 of 0.4).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Instructional Videos on Postoperative Respiratory Function in Patients Undergoing Off-Pump Open Heart Surgery

Background: Respiratory function in patients undergoing open heart surgery is disrupted after surgery.  Patient education on managing complications can reduce occurrence or severity of them. A variety of educational tools has been introduced, but there are controversies about the most appropriate tools. Aim: Determine the effect of instructional videos on respiratory function of the patients af...

متن کامل

Comparing the Effect of Aromatherapy with Salvia officinalis and Topical Lidocaine Gel on Pain Intensity During Insertion of Vascular Catheters in Hemodialysis Patients

  Background and purpose: Hemodialysis is a common treatment for end-stage renal failure, and cannulation causes considerable pain. Topical lidocaine gel and aromatherapy as a complementary medicine are used to relieve the pain. Aromatherapy is associated with fewer side effects than medication, so, the present study was conducted to compare the effect of aromatherapy with Salvia officinalis a...

متن کامل

Complications of Peripheral Intravenous Catheters During 72 Hours After Insertion

Introduction: Peripheral Intravenous catheterization is the most commonly used invasive treatment method in patients admitted to the hospitals, but it has some complications. The indwell time of catheter is one of the factors associated with the occurrence of complications, especially phlebitis. In spite of the instructions for replacing the catheters after 72 hours, sometimes the complications...

متن کامل

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 3  شماره 

صفحات  -

تاریخ انتشار 1999