Microleakage in Resin Composite Restoration following Antimicrobial Pre-treatments with 2% Chlorhexidine and Clearfil Protect Bond

نویسندگان

  • Hisham Hameed
  • Biju P Babu
  • V M Mohammed Sagir
  • Kennet J Chiriyath
  • Jones Mathias
  • A P Shaji
چکیده

AIM To evaluate microleakage in resin composite restorations after antimicrobial pre - treatments. MATERIALS AND METHODS Forty freshly extracted non carious human premolars were procured. In all forty premolar specimens, class V preparation of standard dimension were prepared and were randomly divided into three experimental and one control group. In all control and experimental groups the class V preparations were restored with FILTEK Z350 composite restorative material. The experimental groups included different self etching primers and 2% Chlorhexidine gluconate. The control group included Xeno III and no antimicrobial pre-treatment was done for the control group. Thereafter these specimens were thermocycled, dried and sealed with nail varnish, leaving 1mm around the restoration and immersed in 0.5% basic fuchsin for 24 hours and then the specimens were subjected for microleakage evaluation. The results were statistically analyzed by Kruskal Wallis Test and Mann Whitney 'U' test. RESULTS Results indicate that group II (2% chlorhexidine gluconate group) had the minimum mean value (15.05) and group III(Clearfil protect Bond group) and IV(control group) had the maximum mean microleakage at the enamel margin (23.00). At the gingival margin the lowest mean microleakage values were obtained with group I (Clearfil SE bond group) and group II (2% chlorhexidine gluconate) (20.25) and highest with group III and group IV (20.85). The difference was not statistically significant both at the enamel margin and the dentin margin (p>0.05). INTERPRETATION & CONCLUSIONS Within the limitations of this in-vitro study, we conclude that: None of the materials tested in this study completely eliminated microleakage at the enamel and at the gingival margin.All of the tested materials provided better sealing at the enamel margin than at the gingival margin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage of Class II posterior composite restorations with gingival margins placed entirely within dentin.

PURPOSE Composite restorations are more frequently being placed with margins apical to the cementoenamel junction. However, margins within dentin are prone to microleakage. The purpose of this in vitro study was to evaluate various restorative procedures in terms of their ability to reduce microleakage in posterior composite restorations with gingival margins within dentin. We also examined the...

متن کامل

Microleakage of Composite Resin Restorations Using a Type of Fifth and Two Types of Seventh Generations of Adhesive Systems: A Comparative Study

Introduction: In recent dentin adhesive systems etching of enamel/dentin are achieved simultaneously. The objective was to evaluate the microleakage of composite restorations using Single Bond2 (5th generation), Clearfil S3 Bond and G Bond (7th generation). Methods: Class V cavities were prepared on  45 extracted intact premolars with gingival margins at the cementoenamel junction and they were...

متن کامل

Efficacy of Hydrophobic Layer on Sealing Ability of Dentin Adhesive Systems in Class V Composite Resin Restorations

BACKGROUND AND AIMS Adhesive permeability is hindered by application of an additional layer of hydrophobic resin, which increases its concentration within the hydrophilic layer, reduces its affinity to water, and enhances its physical prop-erties. The aim of the present study was to evaluate the effect of a hydrophobic layer on the microleakage of class V composite restorations using different ...

متن کامل

Microleakage of Composite Resin Restorations Using a Type of Fifth and Two Types of Seventh Generations of Adhesive Systems: A Comparative Study

Introduction: In recent dentin adhesive systems etching of enamel/dentin are achieved simultaneously. The objective was to evaluate the microleakage of composite restorations using Single Bond2 (5th generation), Clearfil S3 Bond and G Bond (7th generation). Methods: Class V cavities were prepared on 45 extracted intact premolars with gingival margins at the cementoenamel junction and they were ...

متن کامل

Microleakage of class V resin composites using various self-etching adhesives: an in vitro study.

BACKGROUND AND AIMS Microleakage has been identified as a significant problem with composite restorations because of interfacial gap formation which can result in tooth discoloration, recurrent caries, possible pulpal involvement and restoration replacement. Aim of this study is to evaluate the microleakage of self-etch adhesive system at the coronal and apical margins of class V resin composit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015