A Novel Ground Fault Non-Directional Selective Protection Method for Ungrounded Distribution Networks

نویسندگان

  • Ricardo Granizo
  • Francisco R. Blánquez
  • Emilio Rebollo
  • Carlos A. Platero
  • Josep M. Guerrero
چکیده

This paper presents a new selective and non-directional protection method to detect ground faults in neutral isolated power systems. The new proposed method is based on the comparison of the rms value of the residual current of all the lines connected to a bus, and it is able to determine the line with ground defect. Additionally, this method can be used for the protection of secondary substation. This protection method avoids the unwanted trips produced by wrong settings or wiring errors, which sometimes occur in the existing directional ground fault protections. This new method has been validated through computer simulations and experimental laboratory tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review of Ground Fault Protection Methods for Grounded, Ungrounded, and Compensated Distribution Systems

This paper reviews ground fault protection and detection methods for distribution systems. First, we review and compare medium-voltage distribution-system grounding methods. Next, we describe directional elements suitable to provide ground fault protection in solidlyand lowimpedance grounded distribution systems. We then analyze the behavior of ungrounded systems under ground fault conditions a...

متن کامل

Applying Frequency Response method for contact Rails Fault Diagnosing in Ungrounded Electrical Railway System

Abstract General faults in regular electrical railways system could be detect by implementing the specific protection functions such as ground fault or sensitive earth fault. Otherwise, in ungrounded electrical railway systems which using both feeding and return contact rail at the same time, fault detection cannot done with above-mentioned function. Due to recent growth in electrical railway ...

متن کامل

A Novel Protection Method for Single Line-to-Ground Faults in Ungrounded Low-Inertia Microgrids

Abstract: This paper proposes a novel protection method for single line-to-ground (SLG) faults in ungrounded low-inertia microgrids. The proposed method includes microgrid interface protection and unit protection. The microgrid interface protection is based on the difference between the zero-sequence voltage angle and the zero-sequence current angle at the microgrid interconnection transformer ...

متن کامل

Wavelet based Fault Detection Method for Ungrounded Power System with Balanced and Unbalanced load

Modern spectral and harmonic analysis is based on Fourier transforms. However, these techniques are less efficient in tracking the signal dynamics for transient disturbances. Consequently, the wavelet transform has been introduced as an adaptable technique for non-stationary signal analysis. Although the application of wavelets in the area of power system engineering is still relatively new, it...

متن کامل

Fault Detection and Location in DC Microgrids by Recurrent Neural Networks and Decision Tree Classifier

Microgrids have played an important role in distribution networks during recent years.  DC microgrids are very popular among researchers because of their benefits. Protection is one of the significant challenges in the way of microgrids progress. As a result, in this paper, a fault detection and location scheme for DC microgrids is proposed. Due to advances in Artificial Intelligence (AI) and s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015