A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields.

نویسندگان

  • C Mae Wong
  • P J E van Dijk
  • I A Laing
چکیده

BACKGROUND Two devices are available for making transcutaneous estimates of serum bilirubin (SBR): the Minolta AirShields JM102 and the new SpectRx BiliCheck. OBJECTIVES (a) To measure how well the readings produced by these devices agree with SBR measured in the laboratory; (b) to estimate for each device, the proportion of infants with clinical jaundice who would require blood sampling if the device was used as a screening tool to detect infants with SBR > or = 250 micromol/l. DESIGN Prospective cohort study of jaundiced infants who required SBR at < or = 20 days of postnatal age. Those who had received phototherapy or exchange transfusion were excluded. SETTING Tertiary neonatal service in South-East Scotland. INTERVENTIONS Within 30 minutes of SBR sampling, transcutaneous bilirubinometry was performed using one Minolta and two SpectRx devices (designated A and B). RESULTS Sixty-four neonates were enrolled, 19 of which were preterm (31-35 weeks). The 95% confidence intervals of a device reading corresponding to SBR were +/- 66.7, +/- 67.9, and +/- 66.4 micromol/l respectively. Using the devices to identify all SBR > or = 250 micromol/l would reduce SBR sampling by 23%, 16%, and 20% respectively. CONCLUSIONS Given that SBR levels range from 50 to 400 micromol/l in jaundiced infants, the 95% confidence intervals of the devices are wide at +/- 67 micromol/l. The SpectRx can be used as a screening tool for hyperbilirubinaemia but there is no advantage in using it over the Minolta.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two transcutaneous bilirubinometers--Minolta AirShields Jaundice Meter JM103 and Spectrx Bilicheck--in Thai neonates.

Transcutaneous bilirubin (TcB) has been reported to have a high correlation with serum bilirubin. The objectives of this study were: (1) to compare the accuracy of two transcutaneous bilirubinometer (Minolto AirShields Jaundice Meter, JM103 (JM) and SpectRx, Bilicheck (BC) in estimating total serum bilirubin (TSB) levels; and (2) to assess the predictive ability of transcutaneous bilirubin in r...

متن کامل

Archives of Disease in Childhood Fetal and Neonatal Edition 2002;87:F137-F140

TOP ABSTRACT METHODS RESULTS DISCUSSION REFERENCES Background: Two devices are available for making transcutaneous estimates of serum bilirubin (SBR): the Minolta AirShields JM102 and the new SpectRx BiliCheck. Objectives: (a) To measure how well the readings produced by these devices agree with SBR measured in the laboratory; (b) to estimate for each device, the proportion of infants with clin...

متن کامل

BiliCheck transcutaneous bilirubinometer: a screening tool for neonatal jaundice in the Chinese population.

OBJECTIVE To verify the usefulness of the BiliCheck transcutaneous bilirubin meter as a screening device for neonatal jaundice in a Chinese population compared with the Minolta bilirubin meter. DESIGN A prospective correlation study that compared transcutaneous bilirubin measurements with serum bilirubin levels. SETTING Obstetric ward and a neonatal unit of a regional hospital in Hong Kong....

متن کامل

Transcutaneous Bilirubinometer

Neonatal jaundice occurs in nearly 70% of term and 80% of preterm babies. Management of jaundiced neonates often requires measurement of total serum bilirubin (TSB). Total serum bilirubin (TSB) is commonly determined by spectro-photometric methods by analyzing plasma or serum sample. Such techniques require drawing of blood causing pain and trauma to the neonate. In addition, there is a wide ra...

متن کامل

The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran

The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 2002