Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database Application

نویسنده

  • Bruce Quimby
چکیده

Laboratories that perform toxicology screens are challenged by the requirement to look for large numbers of target compounds in samples that contain complex matrix interferences. GC/MS methods are widely used and accepted for this analysis. Full-scan EI methods offer many advantages for broad-range screening, such as unlimited numbers of targets, full-spectrum identity confirmation, and library searching for identification of nontargets. With recent advances in GC/MS technology, there are several opportunities to substantially increase the number of targets screened for and simultaneously reduce the time required per sample. With the system described here, samples are screened for 725 compounds using Agilent's G1674AA Forensic Toxicology DBL. Data review time is substantially reduced using Agilent Deconvolution Reporting Software. Post-run bakeout of heavy-matrix compounds is replaced with column backflushing, which is faster and reduces system maintenance. Run time is reduced by using a fast GC run (9.75 min injection to injection) and simultaneously collecting scan, SIM, and NPD data. The scan data is deconvoluted and used to identify any of the 725 target compounds. SIM data is used to look for select low-level Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toxicology Screening of Whole Blood Extracts Using GC/Triple Quadrupole/MS

The Agilent 7000 GC/QQQ system can provide both high selectivity and high sensitivity for the analysis of drugs. Low-level detection and confirmation of large numbers of target drugs in blood extracts is possible in a single run. Combined with information from a single quadrupole screening instrument like the Agilent GC/NPD/MSD/DRS system, a much more complete picture of each sample is now poss...

متن کامل

Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database Application Note

Response to homeland security or environmental incidents involving hazardous chemicals requires first, the rapid and accurate identification of the chemical agent(s) involved and second, the quantitative measurement of that agent in large numbers of samples to aid in managing the response. Given the unknown nature of the analytes and the complexity of matrices that could be encountered, develop...

متن کامل

Determining Rest Concentration of Diazinon in Agriculture Products (Melon And Cucmber) with GC-NPD and GC-MS Methods

Introduction: Diazinon is a moderately toxic broad-spectrum organophosphate, with a LD50 of 350 to 400 mg/kg for humans. Diazinon is absorbed through the skin and gastrointestinal tract and is rapidly metabolized within a few hours. Diazinon residues in melons and cucumbers have recently became a major health concern in Iran. Thus we decided to investigate Diazinon levels in melon and cucumbe...

متن کامل

Performance evaluation of thermal desorption system (TDS) for detection of basic drugs in forensic samples by GC-MS.

Stir bar sorptive extraction is an innovative sample extraction technique that can be used to process blood, urine, and tissue samples for routine drug screening in the forensic toxicology laboratory. The Gerstel Twister desorption unit (TDU) system is a multifunctional desorption unit capable of determining the presence of analytes from liquid samples after extraction using the Twister stir ba...

متن کامل

Screening for 171 Volatile Organic Air Pollutants Using GC/MS with Deconvolution Reporting Software and a New Indoor Air Toxics Library Application

A retention-time-locked mass spectral database was created specifically for indoor air analysis by thermal desorption/gas chromatography/mass spectroscopy (TD/GC/MS). This Indoor Air Toxics Database contains locked retention times and mass spectra for 171 volatile and semivolatile organic compounds that are targets in various indoor air methods. In combination with Agilent's Deconvolution Repor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008