Considering the effects of UPS operation with leading power factor loads
ثبت نشده
چکیده
Over the past five years, a new generation of data processing and communications equipment has become prevalent in modern data centers and network operations centers. These newer products provide beneficial increases in processing power and higher-density form factors, resulting in reduced operating costs, conservation of valuable facility space and enhanced capabilities for the enterprise. However, as performance and processing densities increase, so does the critical need to improve the “site friendliness” of the ubiquitous AC-to-DC power supplies that are utilized in today’s blade servers and communications gear. Specifically, it is beneficial to implement power factor correction (PFC) and reduced total harmonic distortion (THD) within these power supplies, which results in a total data center load that greatly reduces disturbances to a building’s electrical system, particularly when compared with data processing systems from a decade ago. At the same time, these new processors contribute toward a green data center by preserving floor space and requiring less power.
منابع مشابه
Operation of multi Carrier microgrid (MCMG) considering demand response
: In this paper, the operation of a future distribution network is discussed under the assumption of a multi-carrier microgrid (MCMG) concept. The new model considers a modern energy management technique in electricity and natural gas networks based on a novel demand side management (DSM) which the energy tariff for responsive loads are correlated to the energy input of the network and changes ...
متن کاملActive Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملModified Bi-directional AC/DC Power Converter with Power Factor Correction
Most existing power converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...
متن کاملElectrical Load Manageability Factor analyses by Artificial Neural Network Training
On typical medium voltage feeder, Load side management means power energy consumption controlling at connected loads. Each load has various amount of reaction to essential parameters variation that collection of these reactions is mentioned feeder behavior to each parameter variation. Temperature, humidity, and energy pricing variation or major event happening and power utility announcing to th...
متن کاملOperation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads
This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network ...
متن کامل