Effect of Patient Characteristics on Vessel Enhancement at Lower Extremity CT Angiography
نویسندگان
چکیده
Objective To evaluate the effect of patient characteristics on popliteal aortic contrast enhancement at lower extremity CT angiography (LE-CTA) scanning. Materials and Methods Prior informed consent to participate was obtained from all 158 patients. All were examined using a routine protocol; the scanning parameters were tube voltage 100 kVp, tube current 100 mA to 770 mA (noise index 12), 0.5-second rotation, 1.25-mm detector row width, 0.516 beam pitch, and 41.2-mm table movement, and the contrast material was 85.0 mL. Cardiac output (CO) was measured with a portable electrical velocimeter within 5 minutes of starting the CT scan. To evaluate the effects of age, sex, body size, CO, and scan delay on the CT number of popliteal artery, the researchers used multivariate regression analysis. Results A significant positive correlation was seen between the CT number of the popliteal artery and the patient age (r = 0.39, p < 0.01). A significant inverse correlation was observed between the CT number of the popliteal artery and the height (r = -0.48), total body weight (r = -0.52), body mass index (r = -0.33), body surface area (BSA) (r = -0.56), lean body weight (r = -0.56), and CO (r = -0.35) (p < 0.001 for all). There was no significant correlation between the enhancement and the scan delay (r = 0.06, p = 0.47). The BSA, CO, and age had significant effects on the CT number (standardized regression: BSA -0.42, CO -0.22, age 0.15; p < 0.05, respectively). Conclusion The BSA, CO, and age are significantly correlated with the CT number of the popliteal artery on LE-CTA.
منابع مشابه
ESC GUIDELINES ESC Guidelines on the diagnosis and treatment of peripheral artery diseases Document covering atherosclerotic disease of extracranial carotid and vertebral, mesenteric, renal, upper and lower extremity arteries
Computed tomography angiography The contrast agent for computed tomography angiography (CTA) is injected through a peripheral vein with an 18 G needle. The risks include the usual ones for contrast medium, particularly contrast allergy. Patient preparation for CTA is similar to that in other contrast-enhanced studies and includes the disclosure of information on contrast risks and an assessment...
متن کاملImage Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
OBJECTIVES The purpose of this study was to assess image quality and radiation dose of lower extremity CT angiography (CTA) with 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction (SAFIRE). METHODS Lower extremity CTAs were performed on 44 patients: 22 patients were examined using protocol A (120 kVp, pitch of 0.85 and 120 ml of contrast agent on a first-generation ...
متن کامل[Optimal scan timing in 64-row MDCT angiography of the lower extremities: 2-point ROI detection bolus-tracking method].
In CT angiography of the lower extremities, we have developed a 2-point ROI detection bolus-tracking method (2ROI-BTM) to provide the optimal contrast medium concentration and reduce contrast medium. The time to reach the ankle from the abdominal aorta was 22.5 s (95% central range, 14.6-40.1 s). The mean scan time was 13.6 s (range, 11.5-15.0 s). In the 2ROI-BTM (n=78), the mean CT number was ...
متن کاملطراحی پروتکل MR انژیوگرافی اندام تحتانی با استفاده از دستگاه 1.5MRI تسلا
Background and purpose: Ôn time diagnosis and treatment of lower limb diseases are of crucial importance to the patients. Çonventional angiography is the standard procedure of diagnosis, which is followed by different problems such as, X-ray hazards, sensitivity to contrast drugs and complications of opening vessel. Doppler ultrasonography has low differentiation power. MR angiography is a s...
متن کاملEvaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography
Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...
متن کامل